isar -
Installation and Servicing
GENERAL
1
BOILER WATER CIRCUIT DIAGRAMS
INTRODUCTION
The isar m30100 is a wall mounted, full sequence, automatic
spark ignition, low water content, fanned flue, high efficiency,
condensing, combination gas boiler.
Note.
Due to the high efficiency of the boiler a plume of water
vapour will form at the terminal during operation.
Central heating (CH) output is fully modulating with a range of
8.8 to 23.4kW (30,000 to 80,000 Btu/h)
Instantaneous domestic hot water (DHW) output is also fully
modulating with a maximum of 29.3kW (100,000 Btu/h)
The boiler is supplied fully assembled with DHW plate heat
exchanger, diverter valve, circulating pump, pressure gauge,
safety valve and CH expansion vessel.
Variable CH and DHW temperature controls are fitted on the
user control and the boiler features a DHW preheat facility.
The boiler casing is of white painted mild steel with the user
controls capable of being mounted remotely from the boiler if the
option is required.
The boiler temperature controls are visible at the bottom RHS of
the front panel.
The heat exchanger is of cast aluminium.
The boiler is suitable for connection to fully pumped, sealed
water systems ONLY. Adequate arrangements for completely
draining the system by provision of drain cocks MUST be
provided in the installation pipework.
Pipework from the boiler is routed downwards as standard, but
may be routed upwards behind the boiler using the stand-off
frame (supplied in a separate kit).
OPERATION
With no demand for CH, the boiler fires only when DHW is
drawn off, or periodically for a few seconds without any DHW
draw-off, in order to maintain the DHW calorifier in a heated
condition.
When there is a demand for CH, the heating system is supplied
at the selected temperature of between 30
o
C and 82
o
C, until
DHW is drawn off. The full output from the boiler is then
directed via the diverter valve to the plate heat exchanger to
supply a maximum DHW draw-off of 12 l/min at 35
o
C
temperature rise.
At low DHW draw-off rate the maximum temperature is limited to
65
o
C by the modulating gas control.
Refer also to Frame 1 - 'Boiler Water Circuit Diagrams'
The boiler features a comprehensive diagnostic system which
gives detailed information on the boiler status when operating,
and performance of key components to aid commissioning and
fault finding.
Central Heating Circuit
Expansion
vessel
Automatic
air vent
Gas valve
Plate heat
exchanger
Pump
Safety
relief valve
Condensate
'S' trap
Diverter
valve
Water
pressure
gauge
Sump
Fan
Burner
CH Flow
Gas
Condensate drain
Discharge pipe
CH Return
Domestic Hot Water Circuit
Expansion
vessel
Automatic
air vent
Heat
exchanger
Gas valve
Pump
Safety
relief valve
Condensate
'S' trap
Diverter
valve
Water
pressure
gauge
Sump
Fan
Burner
DHW Hot out
Gas
Condensate drain
Discharge pipe
Ecl 2388
DHW Cold in
Plate heat
exchanger
Heat
exchanger
Содержание isar m30100
Страница 1: ......