22
Henrad SE FF
- Installation
General arrangement
1. A
maximum
of 3 extension ducts (one
suitably cut) plus the standard flue duct may
be used together.
2. Flue extensions of greater length than 1m
(39") should be supported with the bracket
provided, suitably adjusted. Refer to Frame
31.
INSTALLATION
This plate allows neat concealment and full compression of the
rubber seal. Its use is not essential if the flue hole and flue ducts
have been accurately cut and the outside wall face is flat.
1. Position the terminal wall plate over the terminal.
2. Drill 4 fixing holes with a 7mm (
1/4
") masonry drill.
3. Insert the 4 plastic plugs provided.
4. Secure the plate with 4 of the No.10 x 2" screws provided.
Note.
If the terminal is less than 2m (6' 6") above ground level,
an approved terminal guard should be fitted. Refer to the Flue
Installation, Page 7.
30 TERMINAL WALL PLATE
31 FLUE EXTENSION DUCTS - For flue lengths greater than 600mm
32
FLUE EXTENSION DUCTS - continued
FLUE EXTENSION DUCT KIT CONTENTS.
INST
ALLA
TION
Use a maximum of 3m extended flue ONLY
Note.
Side flue shown