In cases of repeated or continuous shutdown a CORGI registered
installer or in Ireland a competent person should be called to
investigate and rectify the condition causing this and carry out an
operational test. Only the manufacturers original parts should be
used for replacement.
Minimum Clearances
Clearances of
200mm (8"
) above,
100mm (4"
) below,
10mm (
3
/
8
"
)
at the sides and
450mm (17
3
/
4
") at the front of the boiler casing
must be allowed for servicing.
The minimum front and bottom clearance allowed when built into
a cupboard is 5mm.
To light the boiler.
If a programmer is fitted refer to separate instructions for the
programmer before continuing.
1.
Switch the electricity supply on.
2.
If the boiler is to be used for CH and DHW position the main
switch (B) as in the following illustration.
Destination Countries: GB, IE
excel HE C24, C28, C32
(Natural Gas Only)
C24
G.C. Appliance No. 47-348-35
C28
G.C. Appliance No. 47-348-36
C32
G.C. Appliance No. 47-348-37
Introduction
The
excel HE
is a wall mounted, room sealed, condensing
combination boiler, featuring full sequence automatic spark
ignition and fan assisted combustion.
Due to the high efficiency of the boiler, condensate is produced
from the flue gases and this is drained to a suitable disposal
point through the plastic waste pipe at the lower rear of the
boiler. A condensate 'plume' will also be visible at the flue
terminal.
The
excel HE
is a combination boiler providing both central
heating and domestic hot water on demand.
S a f e t y
Current Gas Safety (Installation & Use)
Regulations or rules in force.
In your own interest, and that of safety, it is the law that this boiler
must be installed by a CORGI registered installer, in accordance
with the above regulations.
In Ireland, the installation must be carried out by a Competent
Person and installed in accordance with the current edition of
I.S. 813 “Domestic Gas Installations”, the current Building
Regulations and reference should be made to the current ETCI
rules for electrical installation.
It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.
Electricity Supply
This appliance must be earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double-pole switch,
having a 3mm (1/8") contact separation in both poles, serving
only the boiler and system controls. Alternatively, a 3-pin
UNSWITCHED socket may be used. The means of isolation
must be accessible to the user after installation.
Important Notes
z
This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.
z
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
z
If it is known or suspected that a fault exists on the boiler
then it MUST NOT BE USED until the fault has been
corrected by a CORGI registered installer or in Ireland a
competent person.
z
Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.
z
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instructions concerning
use of the appliance by a person responsible for their safety.
z
Children should be supervised to ensure that they do not
play with the appliance.
3.
The boiler will commence the ignition sequence. The green
operational light 1 (E) indicates boiler running for central
heating.
Control of CH Temperature
The output temperature of CH water is adjustable from a
minimum of about 38
o
C to a maximum of about 82
o
C by turning
the knob B. The green operational light 1 (E) indicates boiler
running for Central Heating.
Approx. CH flow temperature for the boiler thermostat settings:
Control of DHW Temperature
The temperature of the DHW leaving the boiler can be varied
from a minimum of about 40
o
C to a maximum of about 65
o
C
(within the power limits for the appliance) by turning the
temperature control knob C. The green operational lights 1
and 3 (E) indicates boiler running for domestic hot water.
All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in
the
Benchmark
Commissioning Checklist. You can check your installer by calling CORGI direct on 01256 372300.
THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE
Ideal Stelrad Group
is a member of the Benchmark initiative and fully supports the aims of
the programme. Benchmark has been introduced to improve the standards of installation and
commissioning of central heating systems in the UK and to encourage the regular servicing of
all central heating systems to ensure safety and efficiency.
B
Minimum (38
o
C)
Maximum (82
o
C)
3
2
1
Winter
Summer
B
201279-6.pmd
02/11/2007, 07:42
62