33
classic m -
Installation & Servicing
SERVICING
53 SIGHT GLASS REPLACEMENT
1.
Refer to Frame 36.
2.
Unscrew the 2 sight glass retaining screws.
3.
Remove the sightglass, gasket and
bracket.
4.
Fit new sight glass, using the new bracket
and gasket supplied.
5.
Reassemble in reverse order.
6.
Check operation of the boiler. Refer to
Frame 36.
54 OVERHEAT THERMOSTAT REPLACEMENT
1.
Refer to Frame 36.
2.
Pull off the electrical leads from the
thermostat body.
3.
Pull the thermostat and clip from the
pipe.
4.
Fit the new thermostat, ensuring that
the clip is securely holding the
thermostat to the flow pipe.
5.
Re-assemble in reverse order.
6.
Check operation of the boiler. Refer to
Frame 36.
Note.
Removal of the collector hood and
flue spigot will facilitate better access.
WARNING.
Beware these components may be
hot if the boiler has recently been run.
Ecl
1642
2
Gasket
Bracket
Sightglass
Ecl 1643