2
classic m -
Installation & Servicing
GENERAL
Boiler Size
m30-50
m50-80
Input
Min
Max
Min
Max
Boiler input 'Q' =
Nett
kW
9.7
16.2
15.8
26.2
CV
Btu/h
33 100
55 300
54 000
89 500
Boiler input 'Q' =
Gross
kW
10.7
18.0
17.5
29.1
CV
Btu/h
36 700
61 400
59 900
99 400
Gas consumption l/s (cu.ft/h)
0.27 (35.4)
0.46 (59.1)
0.45 (57.7)
0.75 (95.7)
Boiler output 'P' =
70 °C Mean water kW
8.8
14.7
14.7
23.4
temperature
Btu/h
30 000
50 000
50 000
80 000
Seasonal efficiency (SEDBUK) *
Band D [ 78.8 ]%
Band D [ 78.6 ]%
Nox classification
class 4
Boiler Size
m30-50
m50-80
Gas supply type and connection
2H-G20-20mbar Rc
1/2
(
1/2
" BSP Female)
Injector size
Stereomatic 5.4mm dia.
Flow connection
22mm copper
Return connection
22mm copper
Maximum static water head
m (ft.)
30.5 (100)
Minimum static water head
m (ft.)
0.45 (1.5)
Electrical supply
230 V ~ 50 Hz
Boiler power consumption
38W
Fuse rating
External: 3A
Internal: F3.15A TL 250V
Water content
litre (gal.)
3.65 (0.8)
Dry Weight
kg (lb.)
43 (95 )
Boiler size
Height
mm (in.)
580 (23)
Width
mm (in.)
390 (15)
Depth
mm (in.)
278 (11)
Flue terminal diameter
mm (in.)
100 (4)
Table 2 - Performance Data
Table 1 - Boiler Data
*
The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by a notified body.
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance, care should be taken when handling edges of sheet steel components.
Note.
Gas consumption is calculated using a calorific value of 38.7
MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett. To
obtain the gas consumption at a different calorific value:-
a.
For l/s - divide the gross heat input (kW) by the gross C.V.
of the gas (MJ/m
3
)
b.
For ft
3
/h - divide the gross heat input (Btu/h) by the gross
C.V. of the gas (Btu/ft
3
)
Key to symbols
GB
= United Kingdom
IE
= Ireland (Countries of destination)
PMS
= Maximum operating pressure of water
C
13
C
33
C
53
= A room sealed appliance designed for connection
via ducts to a horizontal terminal which admits
fresh air to the burner and discharges the
products of combustion to the outside through
orifices which, in this case, are concentric. The
fan is up stream of the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas,
Group H only.