18
classic m -
Installation & Servicing
INSTALLATION
23 MOUNTING THE BOILER
1.
Lift the boiler onto the wall mounting plate, as
shown.
2.
Check the boiler alignment using a spirit level
and adjust as necessary with the jacking screw.
3.
Align the hole in the jacking plate with the pre-
drilled hole in the wall and fix in position with
the No.10 x 2" screw provided.
24 CONNECTING THE FLUE TO THE BOILER
1.
Insert the flue assembly through the prepared hole in the
wall.
2.
Locate the flue turret on the top of the boiler, ensuring
that the turret gasket is in place.
3.
Locate the flue into the turret.
4.
Secure the flue turret on top of the boiler by inserting the
open ends of the turret
clamp under the 2 studs and
fixing it in the middle with
the single M5 x 10mm pozi-
hex screw provided.
5. Flues over 1 metre long.
Fix the flue support bracket
to the wall, using the wall
plug and wood screw. For
standard installations use
the short wood screw.
If the stand-off option is
used, secure the support
bracket using the spacer
bracket and long wood
screw.
Ecl
1592
1
gasket
2
4
INST
ALLA
TION
Содержание Classic m3050
Страница 1: ......