Ideal AKE GASTRO A Series Скачать руководство пользователя страница 2

 

REPAIR MANUAL 

REFRIGERATION UNIT 

– ELECTRICS 

 

Rev

. 21B

 

RM-Refrigeration Unit - electrics_EN 

page 2 of 25

 

This manual contains the repair manual for the built-in 

electrical components

 that are installed in the 

following products/models: 

 

Air Tower 

EBS SB 

Papilio 

Vario presenter 

AKV 

Euro 

Praline 

Vitrine Switch GS 

AZ 

Flantastic 

Salatbar Duo 

Vitrine WK / Switch WK 

BAK G-xx 

Gastro A-xx 

Salatbar Duo Switch 

WHV 

BAK KSL G-xx 

Gastro EC 

Salatbar Single 

UKW SB 

BAK L G-xx 

Gastro G-xx 

Salatbar Single Switch 

 

BAK L G-xx 

Gastro G-xx KL 

Snack 

 

Bakery 

Gastro HCG-xx 

SnackLine Cool 

 

Bakery H-xx 

Gastro HCOE-xx 

Snacky Bistro 

 

Bakery Kombi 

Gastro O-xx 

Snacky Cool 

 

Bakery S 

Green A-xx 

Snacky WK 

 

Brillant KR 

Green FSV 

Sushi Tower 

 

Cake Tower 

Green G-xx 

Sushi-In 

 

Caleo 

Green KSL G-xx 

Switch Flaps 

 

Classic 

Green L G-xx 

Take Away Basic 

 

Cold Flaps 

Green O-xx 

Take Away Cool 

 

Convenience Tower 

Hot Flaps 

Tropical Flaps 

 

Cool Bottle 

KGU G-xx 

Tropical Switch Flaps 

 

Crush 

KGW G-xx 

UKW 

 

Delicious Sushi 

KP 

UKW Switch / W-WK 

 

EBS 

cooling tower 

Vario Food Counter 

 

Note:

 

“xx” = different height/width of the model 

 

 

Содержание GASTRO A Series

Страница 1: ...mment Translated version of original document Language English Copyright 2021 AKE Ausseer K lte und Edelstahltechnik GmbH The contents of this publication may not be reproduced in whole or in part in...

Страница 2: ...Single UKW SB BAK L G xx Gastro G xx Salatbar Single Switch BAK L G xx Gastro G xx KL Snack Bakery Gastro HCG xx SnackLine Cool Bakery H xx Gastro HCOE xx Snacky Bistro Bakery Kombi Gastro O xx Snacky...

Страница 3: ...2 2 Parts of control unit ST501 9 3 2 3 Condensing unit parts 10 3 3 Repair of the control unit 11 3 3 1 Replacement of controller display 12 3 3 2 Replacement of controller board 12 3 4 Repair of th...

Страница 4: ...in any way sent and published in any form 1 1 Release notes Version Created Comments 21A 01 2021 First version of the original description in German 21B 08 2021 Change of document name refrigerated di...

Страница 5: ...at can have an impact on the health of persons Failure to observe these safety instructions can lead to serious injuries This symbol with the comment INFORMATION refers to supporting information and p...

Страница 6: ...ling refrigerant Chapter 1 8 Chapter 1 9 must be observed and understood 2 2 Repair equipment test equipment material 2 2 1 Tool Screwdriver set slotted cross TORX version Allen key set Spanner set so...

Страница 7: ...ck your obligations in accordance with the national WEEE provisions Sorted disposal is mandatory in any case Additional disposal information can be found in the respective operating manual of the appl...

Страница 8: ...nents The power supply must be disconnected before all cleaning and service work To do this unplug the unit or disconnect all poles from the power mains 3 2 Overview of components All electrical compo...

Страница 9: ...9 4 ZB cable connection RJ45 9 2 Display ST521 X LED transformer not shown Exploded view of control unit ST200F 3 2 2 Parts of control unit ST501 Overview of all spare parts of the control unit ST501...

Страница 10: ...of 25 3 2 3 Condensing unit parts Overview of all spare parts of the condensing unit No Description article No Description article 1 1 1 Fan motor 1 1 6 Compressor 1 1 2 Condenser fan 1 1 5 Capacitor...

Страница 11: ...trol unit Unplug the power cord from the connection of the controller housing Release the unlocking clip of the connector Remove the locating screws of the controller housing and pull the entire contr...

Страница 12: ...ol unit St rk ST501 Controller housing complete St rk ST501 display St rk ST521 display Put the new original replacement display back into the housing secure it with the locating screws and connect it...

Страница 13: ...out of the lower tray support Symbolic photo Make sure that the unit is not pulled completely out of the suspension Damage to the condensing unit may occur if it is dropped Lift the condensing unit o...

Страница 14: ...denser fan 1 1 7 Refrigerant collector 1 1 3 Power distributor for motor 1 1 8 Condenser 1 1 4 Dryer 1 1 9 Terminal box 1 1 5 Capacitor 1 1 10 Protective grating fan Exploded view condensing unit Depe...

Страница 15: ...blade To replace the condenser fan all the steps from Chapter 3 4 must be completed first Remove all screws from the fan grille and lift the entire fan from the condenser Remove all screws from the f...

Страница 16: ...grille as shown Remove the necessary cables of the fan motor from the terminal box Terminal box distribution box Terminal box wiring Place the new fan motor in the correct installation position in th...

Страница 17: ...evaporator unit The described work steps may differ from your unit Disassemble remove all shelves extendible drawers etc to access the evaporator unit Fold up the protective plate evaporator cover Re...

Страница 18: ...de of the fan housing remove the locating screws and dismantle the associated fan guard grille Symbolic photo Inside of fan housing Fan guard grille Remove the defective fan from the inside of the fan...

Страница 19: ...remove all cable ties from the cable harness Remove the wiring from the control unit circuit board and pull the entire control cable out of the tubing Remove the sensor from the support plate plastic...

Страница 20: ...cable with suitable fastening materials cable ties and connect it according to the valid product specific wiring diagram 3 6 1 3 Room sensor supply air in the air duct special design Depending on the...

Страница 21: ...anufacturer for more information See also see chapter 1 5 of the operating manual for the respective unit No Description article 01 12 00 LED light strip 01 13 00 LED light strip 01 14 00 LED driver L...

Страница 22: ...he manufacturer for more information See also see chapter 1 5 of the operating manual for the respective unit Use suitable tools to remove all covers housing to access the transformer Disconnect all c...

Страница 23: ...ve unit To be able to disassemble the frame heater the device must be freely accessible from all sides In order to remove the frame heater heating lines it must be disconnected from the control board...

Страница 24: ...Frame heater stuck on In this variant the frame heater is attached to the frame with adhesive aluminium tape Remove the adhesive tape and detach the defective heating cable If necessary remove all cab...

Страница 25: ...hoto After conversion of the unit After the conversion work the unit must be returned to its original condition in order to ensure perfect operation of the unit All steps for commissioning after each...

Отзывы: