background image

bl

LOCATION OF THE REMOTE CONTROL

Use the remote control within a distance of 8 meters/26 feet from the 
appliance, pointing it towards the receiver. Reception is confirmed by a beep.

 CAUTION

  • The air conditioner will not operate if curtains, doors or other 
    materials block the signals from the remote control to the 
    indoor unit.
  • Prevent any liquid from falling into the remote control. Do not 
    expose the remote control to direct sunlight or heat.
  • If the infrared signal receiver on the indoor unit is exposed to 
    direct sunlight, the air conditioner may not function properly. 
    Use curtains to prevent the sunlight from falling on the receiver.
  • If other electrical appliances react to the remote control, either 
    move these appliances or consult your local dealer.
  • Do not drop the remote control. Handle with care.
  • Do not place heavy objects on the remote control, or step on it.

 CAUTION

  • Do not mix old and new batteries or batteries of different types.
  • Do not leave the batteries in the remote control if they are not 
    going to be used for 2 or 3 months.
  • Do not dispose batteries as unsorted municipal waste. Collection 
    of such waste separately for special treatment is necessary.

USING THE REMOTE CONTROL HOLDER
(OPTIONAL)

 • 

The remote control can be attached to a wall or pillar by using a 

    remote control holder (not supplied, purchased separately). 
 • 

Before installing the remote control, check that the air conditioner 

    receives the signals properly.
  • Install the remote control with two screws.
  • For installing or removing the remote control, move it up or 
    down in the holder.

REPLACING BATTERIES

The following cases signify exhausted batteries. Replace old batteries with 
new ones.
  •  Receiving beep is not emitted when a signal is transmitted.
  •  Indicator fades away.

The remote control is powered by two dry batteries (R03/LR03X2) housed in 
the back rear part and protected by a cover.
  1. Remove the cover in the rear part of the remote control.
  2. Remove the old batteries and insert the new batteries, placing the (+) 
    and (-) ends correctly.
  3. Install the cover back on.

8m

MOD

E

S W

ING

TEM

P

S HO

R TC

UT

   FA

N

S PE

E D

   TIM

E R

     O

FF

   RE

S ET

   LO

C K

       L

E D

FOL

L OW

 ME

TIM

E R

  ON

      T

UR B

O

S EL

F CL

E AN

DIR

E CT

S LE

E P

FR E

S H

HANDLING THE REMOTE

CONTROL

NOTE:

When the batteries are removed, the remote control erases all 

programming. After inserting new batteries, the remote control 

must be reprogrammed.

Содержание DUAL MINI-SPLIT

Страница 1: ...nual are for explanation purpose only Your machine may be slightly different The actual shape shall prevail PRO DUAL MINI SPLIT R E M O T E C O N T R O L APPLIES TO THESE MODELS 700021 700023 700024 700025 700026 700027 700028 700029 700807 700808 ...

Страница 2: ...HOW TO USE THE BUTTONS 7 AUTO OPERATION 7 COOLING HEATING FAN OPERATION 7 DEHUMIDIFYING OPERATION 8 TIMER OPERATION 8 HANDLING THE REMOTE CONTROL 11 CONTENTS NOTE All the functions described are accomplished by the unit When there are wide differences between remote control illustration and USER S MANUAL on function description the description of USER S MANUAL shall prevail REMOTE CONTROL SPECIFIC...

Страница 3: ...at cooling or heating operation in the shortest time if the indoor unit does not support this function there is no corresponding operation happened when pressing this button 6SELF CLEAN BUTTON Active Disable Self Clean function Under SELF CLEAN mode the air conditioner will automatically clean and dry the evaporator and keep it fresh for the next operation AUTO COOL DRY HEAT FAN LOW MEDIUM HIGH AU...

Страница 4: ...ed during the heating operation only when the setting mode is HEAT The unit will operate at a setting temperature of 46º F The display window of the indoor unit will display FP Pressing the buttons ON OFF SLEEP SILENCE FP MODE FAN SPEED UP or DOWN while operating will cancel the Silence function 9TIMER ON BUTTON Press this button to initiate the auto on time sequence Each press will increase the a...

Страница 5: ...nged 6 inches for each time the swing button is pressed bnFOLLOW ME BUTTON Push this button to initiate the Follow Me feature the remote display is actual temperature at its location The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again The air conditioner will cancel the Follow Me feature automatically if it does not receiv...

Страница 6: ... MODE FAN TEMP SLEEP SWING DIRECT LED FOLLOW ME TURBO SELF CLEAN ON OFF SILENCE FP TIMER ON TIMER OFF MODE FAN TEMP SLEEP SWING DIRECT LED FOLLOW ME TURBO SELF CLEAN ON OFF SILENCE FP TIMER ON TIMER OFF MODE FAN TEMP SLEEP SWING DIRECT LED FOLLOW ME TURBO SELF CLEAN ON OFF SILENCE FP TIMER ON TIMER OFF MODE FAN TEMP SLEEP SWING DIRECT LED FOLLOW ME TURBO SELF CLEAN ON OFF SILENCE FP TIMER ON TIMER...

Страница 7: ...peed in four steps AUTO LOW MED or HIGH 4 Press the ON OFF button to start the air conditioner MODE FAN TEMP SLEEP SWING DIRECT LED FOLLOW ME TURBO SELF CLEAN ON OFF SILENCE FP TIMER ON TIMER OFF MODE FAN TEMP SLEEP SWING DIRECT LED FOLLOW ME TURBO SELF CLEAN ON OFF SILENCE FP TIMER ON TIMER OFF 3 4 1 1 3 2 2 HOW TO USE THE BUTTONS NOTE 1 In the AUTO mode the air conditioner can logically choose t...

Страница 8: ...ote control transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disappear and the set temperature will re appear on the LCD display window of the remote TO SET THE AUTO OFF TIME 1 Press the TIMER OFF button The remote control shows TIMER OFF the last auto off setting time and the signal H will be shown on the LCD display area Now it is ready to ...

Страница 9: ... of starting operation time and the signal H will show on the display area 2 Press the TIMER ON button to display 6 0H on the TIMER ON display of the remote controller 3 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON indicator remains on and this function is activated TIMER OFF AUTO OFF OPERATION The TIMER OFF feature is useful when you want the unit t...

Страница 10: ...The TIMER ON and TIMER OFF indicator remains on and this function is activated TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house EXAMPLE To start the air conditioner 2 hours after setting and stop it 5 hours after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again...

Страница 11: ... municipal waste Collection of such waste separately for special treatment is necessary USING THE REMOTE CONTROL HOLDER OPTIONAL The remote control can be attached to a wall or pillar by using a remote control holder not supplied purchased separately Before installing the remote control check that the air conditioner receives the signals properly Install the remote control with two screws For inst...

Страница 12: ... answers to most common questions and a complete technical support library please visit www ideal air com All design and specifications herein are subject to change without notice for product improvement Contact Ideal AirTM for details updates and other information DO NOT return this product to the store where you purchased it ...

Отзывы: