- 34 -
Key operation instructions:
1. "
" key:
Short press “
” as the exit key and return to the main page.
In the main interface, long press the "
" button for 3 seconds to turn on/off.
2. "
" mode key:
In the power-on state, press and hold "
" for 3 seconds to switch the working mode.
In the heating (cooling) + hot water mode, in the adjustment setting temperature interface, single press "
" to
switch between the hot water setting temperature and the heating (cooling) setting temperature. When “
”
flashes, it means adjusting the heating (cooling) setting temperature, and “
” is off, it means adjusting the
hot water setting temperature.
3. "
" plus key
When powering on, in the main interface, single press "
" to adjust the current mode setting temperature;
In the main interface, long press the "
" key for 3 seconds to enter the unit status parameter query, cooperate
with the "
" and "
" keys to browse the parameters, and press the "
" key to exit the parameter query.
System parameters table
Code
Parameters’ name
Adjustment
range
Defaults
P01
Return temp difference under heating
and cooling mode
2
℃
~18
℃
2
℃
P02
Return temp difference under hot
Water mode
2
℃
~18
℃
5
℃
P03
Hot water set temp
28
℃
~60
℃
55
℃
P04
Cooling set temp
7
℃
~30
℃
12
℃
P05
Heating set temp
15
℃
~50
℃
50
℃
P06
Set temp for exhaust protection (TP4) 50
℃
~125
℃
110
℃
P07
Set temp for recovery when exhaust
temp is too high (TP0)
50
℃
~125
℃
95
℃
P08
Water temp compensation
-5
℃
~15
℃
3
℃
P09
Defrost frequency
30-120HZ
70HZ
P10
Defrost cycle
20MIN~90MIN
45MIN
Содержание ISW-10 SF1-DN1
Страница 21: ... 21 XD 05BSPM ...
Страница 56: ... 56 By sliding the button you can adjust the setting parameters Function buttons ...
Страница 65: ......