- 42 -
heating
D08
Maximum speed 6 of DC motor under
heating
0~1000
[-16
,
-10) 900
D09
Maximum speed 7 of DC motor under
heating
0~1000
[-23
,
-16) 900
D10
Maximum speed 8 of DC motor under
heating
0~1000
T
<
-23
℃
900
D11
Heating Tw-Tp
(
Tlp
)
target value 1
0~30
T≥14
℃
2
D12
Heating Tw-Tp
(
Tlp
)
target value 2
0~30
[9
,
14)
2
D13
Heating Tw-Tp
(
Tlp
)
target value 3
0~30
[4
,
9)
2
D14
Heating Tw-Tp
(
Tlp
)
target value 4
0~30
[-5
,
4)
2
D15
Heating Tw-Tp
(
Tlp
)
target value 5
0~30
[-10
,
-5)
2
D16
Heating Tw-Tp
(
Tlp
)
target value 6
0~30
[-16
,
-10)
2
D17
Heating Tw-Tp
(
Tlp
)
target value 7
0~30
[-23
,
-16)
2
D18
Heating Tw-Tp
(
Tlp
)
target value 8
0~30
T
<
-23
℃
2
D19
DC motor speed regulation cycle
10~180 S
30S
D20
Motor adjust speed per cycle
0~100 R
10 R
D21
Maximum speed 1 of DC motor under
hot water mode
0~1000
T≥25
℃
500
D22
Maximum speed 2 of DC motor under
hot water mode
0~1000
[10
,
25) 700
D23
Maximum speed 3 of DC motor under
hot water mode
0~1000
[-10
,
10) 900
D24
Maximum speed 4 of DC motor under
hot water mode
0~1000
T
<
-10
℃
900
D25
Hot water Tw-Tp
(
Tlp
)
target value 1 0~30
T≥25
℃
2
D26
Hot water Tw-Tp
(
Tlp
)
target value 2 0~30
[10
,
25)
2
D27
Hot water Tw-Tp
(
Tlp
)
target value 3 0~30
[-10
,
10)
2
D28
Hot water Tw-Tp
(
Tlp
)
target value 4 0~30
T
<
-10
℃
2
D29
Maximum speed 1 of DC motor under
cooling mode
0~1000
T≥38
℃
900
D30
Maximum speed 2 of DC motor under
cooling mode
0~1000
[30
,
38) 800
D31
Maximum speed 3 of DC motor under
cooling mode
0~1000
[25
,
30) 700
Содержание ISW-10 SF1-DN1