TyPe 10 - wiring diagram
XX-XX
PAGE X-X
nOTiCe
This product is protected by one or more of the following patents
:
U.S. LeTTerS PaTenT nO.
5,719,551; 6,011,460; 6,243,004; 6,249,216; 6,275,147; 6,297,731; 6,346,876; 6,392,534; 6,529,124; 6,696,927; 6,756,885; 6,756,886; 6,771,167; 6,812,829; 6,924,750;
7,010,402; 7,031,826; 7,046,126; 7,061,137; 7,068,153; 7,015,830; 7,205,679; 7,224,083; 7,369,936; 7,378,945; 7,489,233; 7,501,937;
Canadian PaTenT nO.
2,320,248; 2,415,023; 2,426,670; 2,414,991; 2,415,011; 2,415,027; 2,415,038; 2,415,041; 2,502,893; 2,451,490;
2,452,296; 2,451,487;
eUrOPean PaTenT nO.
1,053,128;
de
69807-941T2;
U.S.
20020145535; 20060129282; 20060129284; 20040017284; 20080030316; 20090079552;
eP
1500565; 1538038; 1538037;
PATENT
PAGE X-X
Page 13 of 19
ADS-TBSL-PL
20110120
install guide
guides Français disponibles au www.idatalink.com
www.idatalink.com/support
automotive data solutions inc. © 2011
Transponder Bypass
PASSLOCK
MOVE THE FOLLOWING ITEMS IN YOUR
SCHEMATIC WITH ALL LAYERS ON
USE THE FOLLOWING LAYER SPECIFIC ITEMS AS
WIRING AND TEXT TEMPLATES
CONNECT EITHER
IDATALINK
OR
STANDARD WIRING
IDATALINK (RS232) PORT REQUIRED
ON REMOTE STARTER. IF UNAVAILABLE
USE STANDARD WIRING METHOD
LEGEND
Wiring connections not required
when installed in iDatalink mode
* Wiring connection not required in
2-way iDatalink
ACCES
SORY
BRO
WN OR YELL
O
W
IGNITION
PINK
PAS
SL
OCK
WHITE OR PINK/BLA
CK
ACCESSORY (+) INPUT - BLUE/RED
GROUND - BLUE/YELLOW
(NC) GREEN/RED
(NC) GREEN/YELLOW
PASSLOCK - GRAY/RED
GROUND - GRAY/YELLOW
DATA (SWC) - ORANGE
(NC) PINK/BLACK
IGNITION (+) INPUT - PINK
GROUND-OUTPUT WHEN RUNNING - BLUE/WHITE
(NC) NO WIRE
GROUND - BLACK
12V - RED
REMOTE
STARTER
OPTIONAL
ADS-RNG-GM3
REQUIRED FOR
TRANSPONDER BYPASS
APPLICATION
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
GREEN
Connect to pin #1 of
OBDII connector
located under driver
side dashboard.
CONNECTOR LOCATED
AT MAIN IGNITION SWITCH
IDATALINK
NOTE
STANDARD 12 VOLT, IGNITION AND ACCESSORY
STILL REQUIRED FROM THE REMOTE STARTER.
MULTIPLEX CIRCUIT IS CONTROLLED FROM
MODULE USING DATA, THEREFORE NO ADDITIONAL
RELAYS OR RESISTORS REQUIRED.
NOTE
STANDARD 12 VOLT, IGNITION AND ACCESSORY
STILL REQUIRED FROM THE REMOTE STARTER.
MULTIPLEX CIRCUIT IS CONTROLLED FROM
MODULE USING DATA, THEREFORE NO ADDITIONAL
RELAYS OR RESISTORS REQUIRED.
NOTE
STANDARD 12 VOLT, IGNITION AND ACCESSORY
STILL REQUIRED FROM THE REMOTE STARTER.
MULTIPLEX CIRCUIT IS CONTROLLED FROM
MODULE USING DATA, THEREFORE NO ADDITIONAL
RELAYS OR RESISTORS REQUIRED.
NOTE
STANDARD 12 VOLT, IGNITION AND ACCESSORY
STILL REQUIRED FROM THE REMOTE STARTER.
MULTIPLEX CIRCUIT IS CONTROLLED FROM
MODULE USING DATA, THEREFORE NO ADDITIONAL
RELAYS OR RESISTORS REQUIRED.
NOTE
STANDARD 12 VOLT, IGNITION AND ACCESSORY
STILL REQUIRED FROM THE REMOTE STARTER.
MULTIPLEX CIRCUIT IS CONTROLLED FROM
MODULE USING DATA, THEREFORE NO ADDITIONAL
RELAYS OR RESISTORS REQUIRED.
Doc. No.: ##4684##