MiniSmart II
50
Timings: General Purpose Commands
Description
Specific description
Send
Response Data
Response
Time (ms)
General
Purpose
Commands
Get Firmware
Release
Version
78 46 01
02 1A 00 06 49
44 54 45 43 48
20 4D 69 6E 69
53 6D 61 72 74
20 49 49 20 56
31 2E 30 30 02
52 03
6
Enter into
Bootloader
78 46 7A 49
52 46 57 00
02 03 00 15 6A
00 7F 7F 0
Get Serial
Number
06 + 10 bytes ASCII code Serial
Number Or
15 62 00 – No Serial Number
78 46 02
02 0b 00 06 20
32 33 34 3
6
Get Model
Number
USB
78 46 20
02 09 00 06 4D
49 4E 49 3
6
Reset
78 46 49
02 01 00 06 06
06 03
6
Set Remote
Key Injection
Timeout
(78 53 01 01 02
Timeout_H
Timeout_L(Tim
eout_
H Timeout_L
need be 120
seconds ~
3600 seconds))
120 sec
78 53 01 01
02 00 78
02 01 00 06 06
06 03
6
3600 sec
78 53 01 01
02 0e 10
02 01 00 06 06
06 03
6
error command
78 53 01 01
02 00 77
02 03 00 15 6B
00 7E 80 0
6
Get Remote
Key Injection
Timeout
06 78 01 01 02 Timeout_
78 52 01 01 02 07 00 06 78
01 01 02 0
6
Default General
Group
Remote Key Injection T
78 53 00
02 01 00 06 06
06 03
6
Set Date &
Time
Command Body is 78 53 01 50
06 <Date Time>
Where: <Data Time> is 6 bytes
data – Year, Month, Date, Hour,
Minute, Second
78 53 01 50
08 06 99 12
02 01 00 06 06
06 03
6
78 53 01 50
08 06 15 01
02 01 00 06 06
06 03
6
78 53 01 50
06 00 01 01
02 03 00 15 6a
00 7f 7f 03
6
Get Date &
Time
Response Body is 06 78 01 50
06 <Date Time>
78 52 01 50 02 0B 00 06 78
01 50 06 0
6
Review
General Group 06 78 02 01 02 <Timeout
78 52 00
02 0F 00 06 78
02 01 02 E
6