12
Where: <Data Time> is 6 bytes data – Year, Month, Date, Hour, Minute, Second
Set Idle waiting time
Command Body is 78 53 01 05 01 <Time>
Where: <Time> is 0 or 2 seconds ~ 60 seconds (Default is 2 seconds)
Response Body is 06
Note:
•
If Waiting time is 0 and if interface is RS232, Disable device work into Low Power
Consumption status.
•
If Waiting time is Not 0, If Idle status is more than <Time>, if interface is RS232, and if Card is
not Seated, device will enter into Low Power Consumption status.
•
If device received command in Idle status, the waiting time will be reset.
•
If IC card is removed, the waiting time will be reset.
Default General Group (Default All)
Command Body is 78 53 00
Response Body is 06
Below Setting should be reset to default value:
Function Name
Default Value
Note
Remote Key Injection Timeout
120 Seconds
Get Internal Firmware Version
Command Body is 78 31 – Get Internal Version
Response Body is 06 + Version Number
Review General Group
Command Body is 78 52 00
Response Body is 06 78 02 01 02 <Timeout_H> <Timeout_L>50 06<Date Time>
RS232 Group
Note:
Device will use new stop bits after it responds 0x06.
Set Baud Rate
Command Body is 70 53 01 41 01 ASCIIChar
BaudRate
ASCIIChar
9600
4