ID-AL ChronoPlayer - User Guide V1.0
9 Configuration File
Some features are only accessible via a configuration file. This file is a text file (raw text, without formatting)
that can be created with any simple text editor like “Notepad” from Windows, or similar. This file must be
saved with the “ANSI” encoding. Do not use special characters. This configuration file must be named:
config.txt
.
It must be located at the root of the SD card or of the USB flash drive. If this file is missing, the factory
settings are applied by default.
The configuration file allows to perform the following settings:
Table 7: Optional parameters in the configuration file
Parameter Definition
Valid Values
Default Value
Description
#ID:xxx
001 to 127
001
Assign a number to the ChronoPlayer
to use it with other players through
RS-232.
#VOLUME:xx
00 to 64
Last used value
Define the startup volume of the
player.
#RS_MONITORING:x
0: No monitoring
1: “Daisy Chain” mode
2: “Monitoring” mode
3: “Advanced Monitoring” mode
0
Configure the monitoring mode of the
RS-232 serial link.
#BOOT:xxx
000 to 999
000
Define the folder to play on startup.
#INPUTxx:cmd
xx: 01 to 15
cmd:
PLAY
STOP
NEXT_TRACK
PREV_TRACK
FOLDERyyy - yyy: 000 to 999
VOLUME_PLUS
VOLUME_MINUS
RSyyy - yyy: 001 to 999
INPUT01:FOLDER001
INPUT02:FOLDER002
INPUT03:FOLDER003
INPUT04:FOLDER004
INPUT05:FOLDER005
INPUT06:FOLDER006
INPUT07:FOLDER007
INPUT08:FOLDER008
INPUT09:FOLDER009
INPUT10:FOLDER010
INPUT11:FOLDER011
INPUT12:FOLDER012
INPUT13:FOLDER013
INPUT14:FOLDER014
INPUT15:FOLDER015
Assign the commands of the input
contacts.
#BUTTONx:cmd
x: 1 or 2
cmd:
PLAY
STOP
NEXT_TRACK
PREV_TRACK
FOLDERyyy - yyy: 000 to 999
VOLUME_PLUS
VOLUME_MINUS
Rsyyy - yyy: 001 to 999
BUTTON1:VOLUME_MINUS
BUTTON2:VOLUME_PLUS
Assign other commands to the special
buttons of the infrared remote control.
#BAUDRATE:xxxxx
9600, 19200, 38400
19200
Define the baud rate of the RS-232
serial port.
-32-
© 2016, Waves System
Note:
Each parameter is defined on a line starting with the
#
character, followed by the parameter name,
followed by a colon
:
, and at last the associated value. The parameters can be defined in any order. If a
parameter is not defined, the player uses its factory setting by default.
Содержание ChronoPlayer
Страница 1: ...ChronoPlayer User Guide V1 0 July 12 2016 2016 Waves System...
Страница 50: ...ID AL ChronoPlayer User Guide V1 0 50 2016 Waves System...
Страница 51: ...ID AL ChronoPlayer User Guide V1 0 51 2016 Waves System...
Страница 52: ...ID AL ChronoPlayer User Guide V1 0 by 52 2016 Waves System For more information visit our website www id al com...