background image

125kHz Programming Card

125kHz capable card readers can be programmed using a 125kHz programming card.

These cards can only be used to program ICT card readers which have the capability to read 125kHz cards.

Prerequisites

Using a 125kHz programming card to program a card reader requires a suitably configured 125kHz programming
card. These can be ordered from the ICT support team using order code: PRX-PROG-LF.

In order to use a 125kHz card to program a card reader, the reader must meet the following requirements:

Firmware version 1.04.229 or higher .

It is not possible to specifically identify the firmware version on a reader. The version the reader was shipped
with can be checked by contacting ICT Technical Support and providing the reader's serial number.
Alternatively, upgrade the firmware to a known compatible version.

Entering Programming Mode

Programming mode is entered by presenting a 125kHz programming card to the unit within the first 2 minutes of
power being applied. The reader beeps twice to indicate that it has entered programming mode.

Data entry and the programming menu will time out after 2 minutes of no activity and reverts back to normal
activity. Any incomplete programming changes will be lost.

To program the reader:

1.

Present the 125kHz programming card to the reader to enter

Programming Mode

.

2.

Wait for the reader to beep twice.

3.

Present the same card to the reader a number of times in quick succession to indicate the

Address

of the

required

Programming Option

. See the

Programming Option Addresses

table below.

4.

Wait for the reader to beep twice.

5.

Present the same card a number of times in quick succession to indicate the required

125kHz Setting

. The

settings for each programming option are outlined in the tables below.

6.

Wait for the reader to beep twice, indicating the data has been programmed correctly. At this stage the reader
is waiting for a new address to program.

7.

If additional settings are required, repeat the above steps.

An invalid entry will result in a long tone being generated. The data can be entered again, or you can allow the
reader to time out to select another address.

8.

Once complete, allow the programming interface to time out and return to normal operation.

ICT Card Reader | Configuration Guide

32

Содержание Protege

Страница 1: ...ICT Card Reader Configuration Guide...

Страница 2: ...ans electronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege...

Страница 3: ...nfig Example Enable OSDP 23 Config Example OSDP Baud Rate 23 Config Example OSDP Install Mode 24 Config Example Reader Address 24 Config Example Enable Dual LED Mode 25 Config Example LED Colors 25 Co...

Страница 4: ...ming 34 125kHz Reading Mode 34 Wiegand Output Format 34 LED Function 35 Intelligent Tamper Mode 35 Enable ASK EM Cards 35 PIN Data Interface 35 PSK Unscramble 36 PSK Enable 36 Factory Default 36 Discl...

Страница 5: ...strip 2 color control via external LED wiring 16 color selectable for Protege GX function codes and other features programming requires RS 485 connection or Protege Config App Keep alive transmission...

Страница 6: ...For this reason it is best to configure the settings in LoadIT before you begin LoadIT Settings 1 Open LoadIT and configure the following settings 2 From the main window select the Serial Port tab 3...

Страница 7: ...uisites Config App To use the Config App you will need An app account A mobile credential If you already have a Protege Mobile App account and mobile credential product code PRX MCR these same login c...

Страница 8: ...te to the App Store 2 From the search bar enter Protege Config 3 Select the Protege Config App 4 Tap GET Logging In The Protege Config App uses the same account credentials as your Protege Mobile App...

Страница 9: ...Next you will be prompted to create a PIN for use with this account Enter a unique four digit PIN code then re enter the same PIN to verify it 6 From the drop down select how frequently you would lik...

Страница 10: ...are available in the Protege Config App Important Many of the available TLV settings contain advanced configuration options that may render a reader unusable if applied incorrectly Please ensure that...

Страница 11: ...nnected Backlight Level Set the brightness of the keypad backlight for readers with keypads Backlight Level Disabled Very Low Low default setting Medium High Very High Device Mode The Device Mode TLV...

Страница 12: ...d data before sending it Enforce Options Optionally specify a transmission enforcement option Enforce on CSN Enforce the configured Wiegand style on CSN transmission If this option is not enabled CSN...

Страница 13: ...Serial RS485 see above Custom Format Enter the string to configure the output format of data when in custom RS 485 output mode s Site Decimal S Site Hex c Card Decimal C Card Hex e CSN Decimal E CSN H...

Страница 14: ...ock number Key Type Set the key type to type A or type B Keyslot The keyslot to use as the MIFARE Classic sector key Flags Select the Diversify Key option to enable key diversification Diversification...

Страница 15: ...versified If enabled the reader expects the key for the encryption above to be diversified against the card serial number Keyslot The keyslot to link the custom encryption keys that will be used to au...

Страница 16: ...125kHz HID cards using the standard HID format This is the default There is currently no selection option to disable this programming once enabled To disable low frequency flags apply a Hex TLV with h...

Страница 17: ...bits to be interpreted as some formatting character e g 8l ls means the next 8 bits represent the length value l Once this length value has been read from the card the subsequent l bits on the card wi...

Страница 18: ...r slot 11 is the default reader idle color Changing the default colors will mean the reader LEDs no longer display as expected for events and functions which may complicate support requests It is reco...

Страница 19: ...r Address This TLV is only valid for protocols which support addressing ICT RS485 OSDP or Smart Serial The Reader Address TLV allows you to program the reader s address configuration This may be requi...

Страница 20: ...potential to render a reader unusable Keyslot There is currently no preconfigured config app TLV for loading custom encryption keys for non mobile credentials onto the reader This is achieved by apply...

Страница 21: ...rby readers tap Select Reader If the reader is compatible its Broadcast Address _R SERIALNUMBER will be displayed in the list If only the reader model is displayed this reader cannot be configured usi...

Страница 22: ...iously applied config Depending on the outcome the new config may need to be checked or firmware may need to be updated Previous programming may also need to be reapplied if there is a chance that ear...

Страница 23: ...unicate with an OSDP server the reader must have the same baud rate setting as the reader port it is connected to The default reader baud rate is 38400 ICT card readers support the following baud rate...

Страница 24: ...e programmed via TLV configuration This TLV is only valid for protocols which support addressing ICT RS485 OSDP or Smart Serial This can be used to configure an RS 485 reader as an entry 0 or exit 1 r...

Страница 25: ...figuration page and select the appropriate Credential Profile 2 Tap the icon top right to create a new config Give the config a Name 3 Tap Add TLV to open the dropdown 4 Select LED Color Setting and t...

Страница 26: ...rofile 3 Add a new Reader Configuration called ISO14443 Gain for EV2 Tags 4 Tap the Add TLV dropdown and select the Hex option 5 In the Hex field enter the ISO14443 Gain 6 hex code 180106 then tap Sav...

Страница 27: ...to indicate the reader is in boot mode and ready for the firmware update You will have approximately 30 seconds from the time you power the reader to load the firmware Config Example Factory Default...

Страница 28: ...g a Keyslot Hex TLV see page 20 For this example we want to add encryption key FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF to keyslot 2 1 Tap Add TLV and select the Hex option 2 Enter the hex code 03 11 FFFFFFFF...

Страница 29: ...n Linkage Slot 6 Flags AES 256 Decryption Keyslot 2 this is the keyslot where we stored our encryption key Access Credential Slot 7 this is the slot where we stored our DESFire credential configuratio...

Страница 30: ...e to a known compatible version RGB LEDs if configuring LED colors RS 485 wiring if configuring LED colors Config Card Settings Config cards can be configured or ordered with programming configuration...

Страница 31: ...the entry of a custom format string which describes how to interpret data from the card being read Changing this setting can stop a reader from reading cards Consult ICT Support before using this set...

Страница 32: ...s entered programming mode Data entry and the programming menu will time out after 2 minutes of no activity and reverts back to normal activity Any incomplete programming changes will be lost To progr...

Страница 33: ...eping twice to indicate that it has entered the Wiegand Output Format menu 3 Next present the programming card twice corresponding with the 125kHz Setting 2 for 26 Bit Wiegand Wait for the reader to b...

Страница 34: ...to enter Address 2 Setting 125kHz Setting Description Auto 1 When a card is badged the number of bits sent is determined by the information encoded on the card 26 Bit Wiegand 2 Standard 26 Bit Wiegand...

Страница 35: ...nds The following options are available by badging the programming card four times to enter Address 4 Function Setting Disabled 1 Enabled 2 Only enable Intelligent Reader Tamper Mode if the access con...

Страница 36: ...Bit with 8 digit PINs Where possible these combinations should be avoided PSK Unscramble PSK Unscramble enables the reader to read Kantech Tecom and Motorola cards The following options are available...

Страница 37: ...its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced...

Страница 38: ...aimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to...

Отзывы: