ELT-KLES
EliteSuite Eclipse LED Keypad
User Manual | February 2014
17
Stay Arming
This method allows you to remain in the protected area while partially arming the system. Stay zones are zones
that are bypassed when the system is stay armed. For example, when you go to sleep at night, doors and
windows can be armed without arming other zones like motion detectors.
Stay Arming Your System
1.
Check that all zones that are not stay zones are closed and ready to arm.
2.
Press the FNC key then the STAY key (1), and enter your [USER CODE].
3.
The exit delay will start.
Fast Stay Arming
To Fast Stay Arm your system press the FNC key then press and hold the STAY key (1) for two seconds.
Fast Stay Arming must be enabled by your property manager or security company.
Switching from Stay to Regular/Force Armed
If you need to leave your premises and want to arm the system fully you can use the fast exit arming method.
Press the ARM key or press the FNC key then press and hold the FORCE key (2) to switch to exit delay and
arm in either Force or Regular arming.
For this feature to operate, either Fast Force Arming or Fast Regular Arming must have been enabled by your
property manager or security company.
Instant Arming
Instant Arming will arm all zones immediately, ignoring any exit delay.
1.
With the system disarmed, press the FNC key then press and hold the STAY key (1) for 4 seconds.
2.
After two seconds the Exit Delay will begin as per Stay Arming, but after four seconds the Exit Delay is
canceled and the system will be fully armed.
Force Arming
Force Arming allows you to rapidly arm the system without waiting for all zones in the system to close. During
force arming, a forced zone is considered deactivated until it closes, then the system will arm that zone. Force
arming is commonly used when a motion detector is protecting the area occupied by a keypad. For example,
when arming and the motion detector is programmed as a force zone, the system will allow you to arm even if
the zone is open.
1.
Check that all zones that are not force zones are closed and ready to arm.
2.
Press the FNC key then press the FORCE key (2) and enter your [USER CODE].
3.
The Exit Delay will start.
To Fast Force Arm your system, press the FNC key then press and hold the FORCE key (2) for two seconds.
Fast Force Arming must be enabled by your property manager or installation company.
Содержание EliteSuite ELT-KLES
Страница 1: ...ELT KLES EliteSuite Eclipse LED Keypad User Manual...
Страница 25: ......
Страница 26: ......
Страница 27: ......