Thank you for purchasing the USB Ranger. Please read this guide 
thoroughly before installation. 
 
This document applies to Part Numbers: 00-00003, 00-00004, 00-00007, 
00-00011, 00-0013, 00-00014, 00-00015, and 00-00016. 

FCC Radio Frequency Interference Statement Warning 

The USB Ranger has been tested and found compliant with the limits for a 
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
when installed and operated in a commercial environment. The USB 
Ranger generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with this user guide, may cause harmful 
interference to radio communications. Operation of the USB Ranger in a 
residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own expense.  

CE Statement 

We, Icron Systems Inc., declare under our sole responsibility that the USB 
Ranger, to which this declaration relates, is in conformity with European 
Standard EN 55022/A1 Class A, and EN 50082 -1 (IEC 801-2, IEC 801-3, 
IEC 801-4). 

IC Statement 

This Class A digital apparatus complies with Canadian ICES -003. 
 
 
 
 
 
 
 
 
 
 
©2000 Icron Systems Inc. All rights reserved. Icron Systems Inc., the Icron 
Systems Inc. logo, and the Icron Systems Inc. products referred to herein 
are either the trademarks or the registered trademarks of Icron Systems Inc. 
All other trademarks are property of their respective owners. Icron Systems 
Inc. assumes no responsibility for errors that may appear in this manual. 
Information contained herein is subject to change without notice. 

Icron Systems Inc                      www.icron.com                                        Page 15 

 Obtaining Warranty Service 

To obtain warranty service, you must contact Icron Systems Inc. within the 
warranty period for a Return Material Authorization (RMA) number.
Package the product appropriately for safe shipment and mark the RMA 
number on the outside of the package. The package must be sent prepaid to 
Icron Systems Inc. We recommend that you insure it or send it by a method 
that provides for tracking of the package. The repaired or replaced item will 
be shipped to you, at Icron System Inc.’s expense, not later than thirty days 
after Icron receives the defective product. 
 
Address the returned product to: 

RMA Coordinator 
Icron Systems Inc. 
4603 Kingsway, Suite 301  
Burnaby BC Canada V5H 4M4 
(604) 638-3920 

Содержание 100

Страница 1: ...Icron Systems Inc 4603 Kingsway Suite 301 Burnaby BC Canada V5H 4M4 Tel 604 638 3920 Fax 604 638 3930 www icron com 90 00001 A04 USB Ranger Models 100 and 400 User Guide Featuring ExtremeUSB Technology ...

Страница 2: ... 55022 A1 Class A and EN 50082 1 IEC 801 2 IEC 801 3 IEC 801 4 IC Statement This Class A digital apparatus complies with Canadian ICES 003 2000 Icron Systems Inc All rights reserved Icron Systems Inc the Icron Systems Inc logo and the Icron Systems Inc products referred to herein are either the trademarks or the registered trademarks of Icron Systems Inc All other trademarks are property of their ...

Страница 3: ...Inc its suppliers or licensors be liable for any costs of procurement or substitute products or services lost profits loss of information or data or any other special indirect consequential or incidental damages arising in any way out of the sale of use of or inability to use any Icron Sytems Inc product or service even if Icron Systems Inc its suppliers or licensors have been advised of the possi...

Страница 4: ...J45 connectors if using surface cabling OR Category 5 UTP cabling with two information outlets and two Category 5 UTP patch cords with RJ45 connectors if using premise cabling USB device s Icron Systems Inc www icron com Page 13 Item USB Ranger Models 100 and 400 Range over Category 5 UTP 100 meters Host cable USB Type A B 2m LEX connector UTP RJ45 LEX connector USB 1 x USB Type B REX connector UT...

Страница 5: ...xtremeUSB Information Outlet LEX Computer Information Outlet REX Colour Printer Laser Printer Plotter Scanner ExtremeUSB Computer LEX LEX Information Outlet Information Outlet Information Outlet Information Outlet REX REX Keyboard Electronic Whiteboard ExtremeUSB Icron Systems Inc www icron com Page 5 About the USB Ranger The USB Ranger incorporates Icron s ExtremeUSB technology This technology br...

Страница 6: ...emedy Power and link LEDs on the REX and LEX are lit but a USB device does not work Cause a The USB device is malfunctioning b The USB Ranger is malfunctioning c The USB device is not compatible with the USB Ranger 1 Disconnect the USB Ranger 2 Connect the USB device directly to the USB port on the computer 3 If the device does not function properly consult the user documentation for the device OR...

Страница 7: ... computer 3 Ensure the USB Ranger has been recognized as a Generic USB Hub by the computer If it is not recognized contact Icron Technical Support for assistance Ensure that the proper Category 5 UTP cable with straight through conductors is connected between the REX and LEX units Icron Systems Inc www icron com Page 7 USB Cables USB cables have two distinct connectors The Type A connector is used...

Страница 8: ...Unit to the LEX Unit NOTE To ensure proper operation we recommend that only Category 5 Unshielded Twisted Pair UTP cabling be used to connect the LEX to the REX The UTP cabling must have a straight through conductor configuration with no crossover and be terminated with 8 conductor RJ45 connectors at both ends With Surface Cabling 1 Plug one end of the Category 5 UTP cabling not included into the ...

Отзывы: