DL-100-E / DL-101-E / DL-110-E / DL-120-E User Manual Version 1.1.3 Dec 2020
- 32 -
3.7 Filter IP
For limiting the devices to access the DL-100-E logger, users can specifies particular
devices by setting their IP addresses on this page. When the addresses are 0.0.0.0
from IP1 to IP5, all the devices can access the logger. Once any of the 5 IP address
columns is set, only the device with which IP is saved in the list can assess the logger.
Filter Settings
1. Select the radio button for
Add ___.___.___.___ To The List
and type the IP
address for the accessible device in the following text box.
2. Click on the
Submit
button to the setting effect without restarting.
If the IP setting needs be saved for using after repowered, check the checkbox for
Save to Flash before clicking the Submit button.
Delete IP setting
Select the radio button for
Delete IP#
to delete a specified IP or the radio button for
Delete All
to delete all the IP, check the checkbox for
Save to Flash
and then click
the
Submit
button to take the delete operation effect.