MAINTENANCE MANUAL
SAVANNAH S
Doc. No.:
MM-SVNH-EN
Revision:
07
Rev. Date:
07/11/2022
Proj. Ref.:
SVNH S
A/C:
Savannah S
Applies to Generic Serial Number:
yy-mm-54-xxxx
Page:
23/132
DOC
FMM00
the bulb dimensions must be: minimum height of 0.5 times the diameter, minimum width of 1.5 times
the diameter.
1.14.7. Cable nonio tender
The Nonio cable tender is a double stainless steel plate which allows to regulate the cable tension
by changing the holes alignment, with a step-by-step pitch variation of 0.4 [mm]. A bolt with stop nut
is installed and closed to fix the selected length. When changed the cable tension, always control
the wear of the nonio eyelets and the closure of the stop nut.
Figure 4: Nonio cable tender
1.14.8. Hose assembly
Hereafter are shown some pictures of rubber hoses installation and normal closure of the metallic
clamp. The free edge of the rubber must fit correctly on the corrugated pipe (or straight type), the
rubber must not consumed, cut or cracked. The metal clamp must seal and lock the hose and the
pipe respectively and the side of the metal clump must not cut the rubber.
Figure 5: Fuel hose on fitting