5
2.1 JUKI-3711P's Layout
JUKI-3712’s Layout
C
N
5
C
N
6
C
N1
4
JP6
CN9
CN
10
C
N
16
PC104
CN4
CN3
C
N
7
CN12
C
N
8
CN26
JP10
FAN1
82C693A
82C596B
CN1
JP4
JP2
JP3
JP5
C
N
13
DIMM1
CN11
JP
7
JP
8
CN27
C
N
5
C
N
6
C
N
14
JP6
CN9
C
N
10
C
N
16
PC104
CN4
CN3
C
N7
CN12
C
N
8
CN26
JP10
FAN1
82C693A
82C596B
CN1
JP4
JP2
JP3
JP5
C
N
13
DIMM1
CN11
JP
7
JP
8
CN27
6
2.2 CompactFlash Disk Master/Slave Mode
This jumper is used to select CompactFlash Disk device mode.
The CompactFlash used IDE channel 2.
•
JP2 : CompactFlash Disk Mode Setup
JP2
DESCRIPTION
SHORT Master
OPEN
Slave
2.3 Clear CMOS Setup
If want to clear the CMOS Setup(for example forgot the
password you should clear the setup and then set the password
again.),you should close the JP3 about 3 seconds, then
open again. Set back to normal operation mode.
•
JP3 : Clear CMOS Setup
JP3
DESCRIPTION
OPEN
Keep CMOS Setup
(Normal Operation)
SHORT
Clear CMOS Setup
2.4 Inverter Power Select
This jumper is for LCD inverter power voltage setting.
•
JP4 : Inverter VCC
■ ● ●
1 2 3
JP4 DESCRIPTION
1-2
+12V
2-3
+5V