Split System Heat Pumps
Installation Instructions
2
Installation/ Startup
Information
FIRE, AND ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
Before performing service or maintenance operations
on unit, turn off unit main power switch and install
lockout tag.
!
These instructions must be read and understood
completely before attempting installation.
WARNING
Installation or repairs made by unqualified
persons can result in hazards to you and others.
Installation MUST conform with local building
codes or, in the absence of local codes, with the
the National Electrical Code NFPA 70/ANSI
C1-1999 or current edition and Canadian
Electrical Code Part 1 CSA C.22.1.
The information contained in this manual is
intended for use by a qualified service technician
familiar with safety procedures and equipped
with the proper tools and test instruments.
Failure to carefully read and follow all instruc-
tions in this manual can result in equipment
malfunction, property damage, personal injury
and/or death.
After uncrating unit, inspect thoroughly for hidden damage.
If damage is found, notify the transportation company
immediately and file a concealed damage claim.
Top skid assembly should be left in place until after the unit
is rigged into its final location.
REDUCED EQUIPMENT LIFE AND PERSONAL INJURY
HAZARD
mproper installation, adjustment, alteration, service or
maintenance can void the warranty
.
The weight of the condensing unit requires caution and
proper handling procedures when lifting or moving to
avoid personal injury. Use care to avoid contact with
sharp or pointed edges.
CAUTION
!
Safety Precautions
1. Always wear safety eye wear and work gloves when
installing equipment.
2. Never assume electrical power is disconnected. Check
with meter and disconnect.
3. Keep hands out of fan areas when power is connected
to equipment.
4. R--22 causes frost--bite burns.
5. R--22 is toxic when burned.
Locating The Outdoor Unit:
Check local codes covering zoning, noise, platforms.
If practical, avoid locating next to fresh air intakes, vent or
windows. Noise may carry into the openings and disturb
people inside.
Placement of the unit should be in a well drained area or
unit must be supported high enough so runoff will not enter
the unit.
Do not locate where heat, lint or exhaust fumes will be
discharged on unit (as from dryer vents).
Roof top installations are acceptable providing the roof will
support the unit and provisions are made for water
drainage and the noise or vibration through the structure.
Do not install the unit in a recessed or confined area where
recirculation of discharge air may occur.
Allow sufficient space for airflow clearance, wiring,
refrigerant piping, and servicing unit.
Содержание CHS180
Страница 8: ...Split System Heat Pumps Installation Instructions 8 Fig 5 208 230 Volt Wiring Details...
Страница 10: ...Split System Heat Pumps Installation Instructions 10 Fig 6 460 Volt Wiring Details...
Страница 12: ...Split System Heat Pumps Installation Instructions 12 Fig 6 Auxiliary Box Diagram...
Страница 16: ...Split System Heat Pumps Installation Instructions 16...
Страница 17: ...Split System Heat Pumps Installation Instructions 17...