![background image](http://html1.mh-extra.com/html/icp-das-usa/idcs-8000/idcs-8000_hardware-user-manual_3662252008.webp)
Section 1 Introduction
Feature
8
iDCS-8000 Hardware User Manual (2013/8/14, Rev: 1.43)
1.2
Feature
The iDCS-8000 is an open comprehensive, distributed, process I/O system. It communicates with
controller over industry-standard field buses. It brings benefit for users install to iDCS-8000 in the field, to
close to sensors and actuators, to reduce the installation cost by reducing the cost of cabling.
Comprehensive
The iDCS-8000 offers cost-effective solutions to practically all needs for field-device, including basic
analog and digital I/O, pulse and HART, as well as high-integrity solutions.
Flexible
The I/O modules plugged in iDCS-8000 station can be configured into single or redundant operation.
Users can easily upgrade I/O security in a same station by adding same I/O module and configuring
into redundant operation without any additional wiring.
Wide industry-standard support
The iDCS-8000 provides connectivity to most popular industry-standard to communicate with
controller, and makes iDCS-8000 I/O compatible with various controller or PLC.
The up-to-date I/O
The I/O modules plugged in the iDCS-8000 station will automatically update I/O data to
communication module. This feature not only decreases the delay for updating I/O data but also
acquire the up-to-date I/O data.
I/O redundant switching < 1ms
The iDCS-8000 features a tiny time for I/O redundant switching within maximum 1ms.
Reliable
The iDCS-8000 offers availability-improving feature such as:
-
Hot swap of modules.
A faulty I/O module can be replaced on-line without powering the station
down and without affecting the rest of the station.
-
The iDCS-8000 system also ensures that only right type of modules can be inserted when to
replace on-line.
-
Automatically re-configure same parameter when plugging a replaced module.
-
Redundancy options in all modules, power, communication, I/O.
Содержание iDCS-8000
Страница 1: ...iDCS 8000 Remote Rugged I O System with Redundancy Hardware User s Manual...
Страница 2: ......
Страница 16: ...Section 1 Introduction Installation 16 iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 DN AIH 04...
Страница 24: ...Section 1 Introduction Installation 24 iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43...
Страница 37: ...Digital Input Section 4 I O Module iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 37 4 2 1 4 Pin Assignment...
Страница 43: ...Analog Input Section 4 I O Module iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 43 4 4 1 4 Pin assignments...
Страница 46: ...Section 4 I O Module Analog Input 46 iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 4 4 2 4 Pin assignments...
Страница 49: ...Analog Input Section 4 I O Module iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 49 4 4 3 4 Pin assignments...
Страница 52: ...Section 4 I O Module Analog Input 52 iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 4 4 4 4 Pin assignments...
Страница 61: ...Analog Output Section 4 I O Module iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 61 4 5 2 4 Pin assignments...
Страница 64: ...Section 4 I O Module Pulse Input 64 iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 4 6 1 4 Pin assignments...
Страница 90: ...Section 5 Termination Board Pulse Input 90 iDCS 8000 Hardware User Manual 2013 8 14 Rev 1 43 5 5 1 4 Wiring...