Step3: On the “CAN Port Enable” and “CAN1/CAN2 Baud Rate” location, user can set
the CAN Bus, and other prarameters. The detail functions of these parameters
are list below.
[CAN Port Enable]
“Port Enable” :
Enable/Disable the CAN1/CAN2 port.
“Bus Monitoring” :
Set the CAN port into bus monitoring mode. When setting the
CAN port into bus monitoring mode, the CAN port will just receive
CAN/CAN FD messages, no CAN Ack command be sent to the
CAN Bus.
“Non-ISO”:
Non-ISO operation. If this parameter is checked, the module uses
the CAN FD frame format as specified by the Bosch CAN FD
Specification V1.0. Otherwise, CAN FD frame format will follow
according to ISO11898-1.
[CAN Baudrate]
“Arbitration”:
CAN/CAN FD arbitration phase bit rate. Valid range: 10 kbps ~ 1000
kbps.
“Data Phase”:
CAN FD data phase bit rate. Valid range: 100 kbps ~ 3000 kbps
“SP”:
CAN/CAN FD arbitration/data phase bit rate sample point.
Suggested range: 75.00 ~ 87.50 %