I-7565M-FD USB to CAN/CAN FD converter User Manual (version 1.0.0)
Page: 83
Copyright © 2019 ICP DAS Co., Ltd. All Rights Reserved. E-mail: [email protected]
7.4. CAN Error Counter Register
Bit
Symbol Value
Description
7:0
TEC
Transmit error counter
Current value of the transmit error counter (maximum value 255)
14:8
REC
Receive error counter
Current value of the receive error counter (maximum value 127).
15
RP
Receive error passive
0
Below error level. The receive counter is below the error passive
level of 128
1
At error level. The receive counter has reached the error passive
level of 128
31:16
-
-
Reserved