Ceiling Mounting or Wall Mounting
Environment
Operating
Temperature
0 to +50°C
Storage Temperature
-30 to +75°C
Humidity
10 to 90% RH, Non-condensing
Model
CL-212
CL-212-E
CL-212-BLE
CL-212-WF
PM2.5 Measurement
Range
0 to 400 ug/m
3
Resolution
1ug/m
3
Response Time
<=1 min.
CO
2
Measurement
Range
0 ~ 9999 ppm
Resolution
1 ppm
Accuracy
±40 ppm ±3%
Response Time
120 seconds
Warm-up Time
5 minutes
Temperature Measurement
Range
-10 to +50°C
Resolution
0.1°C
Accuracy
±0.6°C
Relative Humidity Measurement
Range
0 to 100% RH, Non-condensing
Resolution
0.1% RH, Non-condensing
Accuracy
±5% RH, Non-condensing
Dew Point
Range
Calculated using temperature and relative humidity
Resolution
0.1°C
System
CO
Alarm
-
CO
2
Alarm
Yes
PM2.5 Alarm
Yes
Real Time Clock
Yes
Data Logger
Yes, 450,000 Records