Page
23
iCool Compact Series | Owners Manual
In an emergency touch the ORANGE
button on the MAIN POWER SWITCH
or switch off the main power switch
and all high voltage electrical power
is removed instantly from the water
pumps and cooling systems.
Please
be sure all users of the spa pools
are familiar with this function.
In the event that any person is in
difficulty in a spa pool or any other
emergency situation arises, push
the button and all machinery will
stop and all high voltage power will
be disconnected.
The Main Power Switch and
Emergency (test) button are at the
bottom of the left hand side panel
and clearly marked.
If you are using your Compact Cool with an iCool
brand fixed spa pool, the pool is provided with
a high quality water pump especially designed
for the purpose. The pumps we provide are
resistant to chlorine and salt water at normal
concentrations, but the use of chemicals should
be kept within the range normally recommended
for swimming pools to prolong the life of the
pump and the titanium heat exchanger tanks
inside the cooling unit.
Emergency Stop
Advice About Pool Chemicals
The iCool residual earth leakage protection
system can only protect against devices
actually connected to the iCool. It can not
protect against faults in other unrelated electric
devices in the area. All electric devices in any
pool area must only be connected to a power
supply that has a residual earth leakage device
either at the main switch board or on the device
itself.
Never risk using unprotected electrical
devices near water.
Limits To The Electric Shock
Protection System
Never use bromide as it is highly corrosive to all
materials and can cause irritation to athletes
eyes and skin. Bromide is unnecessary in cold
pools because bacterial growth is much slower
at low temperatures. A small amount of chlorine
is all that is needed to keep the water safe.
Use standard pool test strips to determine the
amount needed. If the water is emptied after
each session then no chemicals are needed.
Avoid Harsh Chemicals
Following international safety recommendations
your iCool will not accept water temperature
settings below 5ºC (40ºF) as this would put
athletes using the system at risk of hypothermia.
Also it will not accept heating temperature
settings above 45º C (112ºF) to prevent any
chance of scalding sensitive skin.
Safe Temperature Settings
Содержание Compact Cool 3 Series
Страница 2: ...Page iCool Compact Series Owners Manual 02 ...
Страница 4: ...04 Compact Series ...
Страница 6: ...Page iCool Compact Series Owners Manual 06 The in ice ba ...
Страница 7: ...Page iCool Compact Series Owners Manual 07 ndustry leader in ath technology ...
Страница 31: ...Page 31 iCool Compact Series Owners Manual ...