iCool TurboCool Скачать руководство пользователя страница 8

Page 8

Installation:

Remote Control Touch Screen Option:

TurboCools are supplied either with a Touch Screen integrated into the front panel of the 
machine, or ready wired for either single or double screen remote control panel.

If you ordered a Remote Touch Screen 
Panel, your Turbo will have a special 
multi pin cable socket on the top right 
hand side at the back. Once the cable 
provided with the remote panel is 
plugged into this socket, all functions are 
then controlled from the remote screen 
and all temperature and systems data is 
displayed on the remote screen. 
The Remote panel is supplied with whatever length of data cable you require. If iCool is 
installing your TurboCools the data cable may be directly wired instead of via a plug. 

A Twin Remote Touch Screen Installion

Rear of Cabinet 

STEP 1 Remove the 4 screws on the side of the box

STEP 2 Carefully move the front panel away from the back panel until you can see the 3 cables that you must unplug 
in order to mount the back panel to a wall. 

STEP 3 Unplug the 3 cables as shown so that the front can be separated from the rear panel.

STEP 4 The rear panel has several holes that can be used for screwing to a wall. Select a good position where the 
screen can be easily reached by operators and can be seen from the recovery spa.

STEP 5 Replace the 3 plugs as shown. 

Push the screen power plug number 2 firmly into the screen so that it does not come loose. 

Take care when replacing plug number 1, the data cable for the screen, it has several small pins that must line up 
correctly. 

STEP 6 Replace the front panel, check that the cable from the screen box is plugged in to the TurboCool and test 
that all operations are normal.

Mounting Your Remote Control Touch Screen on a Wall:

 Most iCool users find that it is very 

convenient to have the remote touch screen mounted within the spa pool area for ease of operation so that the 
information on the screen such as temperatures, operation functions and the session timer can be easily seen. 
If you chose this option the remote cabinet can be mounted as shown below.

Содержание TurboCool

Страница 1: ...Installation Operation Manual Turbo Cool Turbo Dual Temp 2012 Models...

Страница 2: ...onnections Page 9 Installing the Pump Page 9 Operating your TurboCool in Cold Mode Pages 10 to 12 Operating your TurboCool in Heat Mode Page 12 Detailed Function Description Page 13 Setting System Pre...

Страница 3: ...larly The main power switch is also part of the electrical safety circuit that can prevent the possibility of electric shock It is essential to test this safety system each time you use the iCool to m...

Страница 4: ...your spa pool is level with or above the pump then there is generally no need to prime the system as the water will flow by gravity to the pump If water does not flow after more than 2 minutes the iCo...

Страница 5: ...her and restart Normally settings above 8 C or or 45 F will not freeze the tanks in any conditions Safe Temperature Settings Following international safety reccomendations your iCool will not accept w...

Страница 6: ...pecial connection to 3 phase power whereas the TurboCool only requires single phase power This is new technology developed by iCool and has many advantages The Intelligent Control System Saves a Lot o...

Страница 7: ...e at least 500 mm apart This spacing can be reduced if they are installed front to back as shown in the illustration at bottom right Plumbing Requirements Just 2 standard 40mm PVC pool water pipes are...

Страница 8: ...ables that you must unplug in order to mount the back panel to a wall STEP 3 Unplug the 3 cables as shown so that the front can be separated from the rear panel STEP 4 The rear panel has several holes...

Страница 9: ...ct your TurboCool is to a wall box with an isolation switch however because the iCool also has an isolation safety switch and an earth leakage safety device built in you can also simply attach a power...

Страница 10: ...ake about 20 seconds and the screen will be black for about 10 seconds Touch the WELCOME screen anywhere and the Main Operating Screen will appear The status bar will flash white while the software lo...

Страница 11: ...ture Selection Screen and accepted 15 C then you will still be seeing the Main Operating Screen NOTE The temperatures can also be displayed in Fahrenheit This is explained on page 14 of this Manual ST...

Страница 12: ...T Do not operate the HEAT COLD switch while the iCool is running Turn off the main power first then change the switch position and turn the main power back on In HEAT mode the fans will immediately lo...

Страница 13: ...ing the Change Setting button this will take you to the Change Settings Screen From here you proceed as described on page 11 Lights Some iCool models have convenient area lighting which is very helpfu...

Страница 14: ...reference To return to the main operating screen touch the BACK 1 button 14 10 25 Systems Preferences Available System Preferences Touching the Home button will take you to a screen that will give yo...

Страница 15: ...screen illustrated below This screen allows you to see the countdown from a distance and also to control it in various convenient ways The current pool and outside temperature will also be displayed...

Страница 16: ...orised operators iCool Systems have attractive user interfaces this makes them easy to use but the downside is that untrained people often like to play with the colourful touchscreens This can upset a...

Страница 17: ...xplanation and advice on how to correct this If the iCool shuts down and displays a System Too Hot Red Warning Screen Your TurboCool is very powerful and can remove as much as 10 000 watts of heat per...

Страница 18: ...r Management System Digital 4 parameter Digital 4 parameter Standard Mounting Available Mounting Options Anti Vibration Feet Wall Frame Ceiling Frame Roller Wheels Anti Vibration Feet Wall Frame Ceili...

Отзывы: