iCool TurboCool Скачать руководство пользователя страница 16

Page 16

Automatic System Shutdown Timer

You  can preset your iCool to shut down at any time up to five hours in the future. This is very convenient 

for coaches and specialists who may want to leave the training area early but want to make sure that 
the system is not left running needlessly. To set this time, touch the

 ”Set Shut Down”

 button and the 

clock digits on the bottom right of the screen will begin to flash as with setting the clock. Use the same up 

down and left right arrows to set the number of hours and minutes you wish to elapse before the system 
automatically shuts down. The system automatically begins the countdown and will stop when the time 
you set reaches zero. The time remaining before shutdown is displayed on the main clock display screen.
As the same arrows are used to set all three time functions, to avoid confusion, a red dot appears next to 
be button of the function being set.

To avoid an unintended shut down next time you use your iCool this timer automatically resets to 0:00 at 
shutdown. It does not keep the previous setting, so there will only be a shutdown if you reset this timer.

14

You can also display the main clock, 
showing the time of day in full screen 
mode by touching the “Display Clock in Full 
Screen” button. 

14:10

14

2:41

 

   Locking Your iCool System to Prevent Tampering

Your iCool has an electronic lock system. 

You should keep this a secret known only to authorised 

operators.

iCool Systems have attractive user interfaces, this makes them easy to use, but the downside is that 
untrained people often like to play with the colourful touchscreens.This can upset all your 
settings and even cause an unintended shutdown.

To lock the screen so that no further inputs can be made, touch and hold the 
iCool icon on the main run screen for more than 10 seconds (you can only lock 
from this main screen). 
A picture of a lock will appear. 
When ever this lock is visible it is not possible to make any inputs or to change 
screens.
To unlock the system and returned to normal, repeat the procedure. Touch and 

hold the iCool icon for more than 10 seconds. The lock will disappear and all functions will return to normal

Intelligent power management saves electricity automatically

All TurboCools are fitted with a fully automatic intelligent power management system that manages the dual heat 

pumps to minimise electricity use. It senses pool and room temperature and other parameters and provides only 
the cooling or heating power that is actually needed at any point and closes down one of the two built in heat pumps 
completely when it is not required. This cuts power use by up to half. Compared to other comparable systems it 
offers large savings during long hold over periods such as over night or weekends, while still maintaing your set 
temperature.
You may notice that the fans change speed and the heat pump compressors start and stop at various times. This 
is a normal function of the power management system as it optimises the operation for best performance and 
economy.

Содержание TurboCool

Страница 1: ...Installation Operation Manual Turbo Cool Turbo Dual Temp 2012 Models...

Страница 2: ...onnections Page 9 Installing the Pump Page 9 Operating your TurboCool in Cold Mode Pages 10 to 12 Operating your TurboCool in Heat Mode Page 12 Detailed Function Description Page 13 Setting System Pre...

Страница 3: ...larly The main power switch is also part of the electrical safety circuit that can prevent the possibility of electric shock It is essential to test this safety system each time you use the iCool to m...

Страница 4: ...your spa pool is level with or above the pump then there is generally no need to prime the system as the water will flow by gravity to the pump If water does not flow after more than 2 minutes the iCo...

Страница 5: ...her and restart Normally settings above 8 C or or 45 F will not freeze the tanks in any conditions Safe Temperature Settings Following international safety reccomendations your iCool will not accept w...

Страница 6: ...pecial connection to 3 phase power whereas the TurboCool only requires single phase power This is new technology developed by iCool and has many advantages The Intelligent Control System Saves a Lot o...

Страница 7: ...e at least 500 mm apart This spacing can be reduced if they are installed front to back as shown in the illustration at bottom right Plumbing Requirements Just 2 standard 40mm PVC pool water pipes are...

Страница 8: ...ables that you must unplug in order to mount the back panel to a wall STEP 3 Unplug the 3 cables as shown so that the front can be separated from the rear panel STEP 4 The rear panel has several holes...

Страница 9: ...ct your TurboCool is to a wall box with an isolation switch however because the iCool also has an isolation safety switch and an earth leakage safety device built in you can also simply attach a power...

Страница 10: ...ake about 20 seconds and the screen will be black for about 10 seconds Touch the WELCOME screen anywhere and the Main Operating Screen will appear The status bar will flash white while the software lo...

Страница 11: ...ture Selection Screen and accepted 15 C then you will still be seeing the Main Operating Screen NOTE The temperatures can also be displayed in Fahrenheit This is explained on page 14 of this Manual ST...

Страница 12: ...T Do not operate the HEAT COLD switch while the iCool is running Turn off the main power first then change the switch position and turn the main power back on In HEAT mode the fans will immediately lo...

Страница 13: ...ing the Change Setting button this will take you to the Change Settings Screen From here you proceed as described on page 11 Lights Some iCool models have convenient area lighting which is very helpfu...

Страница 14: ...reference To return to the main operating screen touch the BACK 1 button 14 10 25 Systems Preferences Available System Preferences Touching the Home button will take you to a screen that will give yo...

Страница 15: ...screen illustrated below This screen allows you to see the countdown from a distance and also to control it in various convenient ways The current pool and outside temperature will also be displayed...

Страница 16: ...orised operators iCool Systems have attractive user interfaces this makes them easy to use but the downside is that untrained people often like to play with the colourful touchscreens This can upset a...

Страница 17: ...xplanation and advice on how to correct this If the iCool shuts down and displays a System Too Hot Red Warning Screen Your TurboCool is very powerful and can remove as much as 10 000 watts of heat per...

Страница 18: ...r Management System Digital 4 parameter Digital 4 parameter Standard Mounting Available Mounting Options Anti Vibration Feet Wall Frame Ceiling Frame Roller Wheels Anti Vibration Feet Wall Frame Ceili...

Отзывы: