The Main Operating Screen 

(above left)

 

appears when you touch the

 WELCOME 

screen.  It provides many options 

which are covered in detail later in this manual, 

To quickly start the system you can simply accept the automatically inserted water temperature setting of 

15ºC

.

The two most commonly used temperatures for ice bath sessions are pre set for your convenience. 

15ºC

 is inserted 

automatically on start up and you can just accept this and continue. If you choose “

Change Settings

” then the 

Temperature Selection Screen

 appears (top right) and 

10ºC

 is automatically set.

If you require a different temperature

 

then after touching the

 “Change Settings”

 button, the screen will change to 

the 

Temperature Selection Screen

 with 

10ºC

 will be inserted automatically. Then 

you have the option of changing to any temperature you require by simply touching 
the up and down arrow buttons. 
As you make changes the new pool water temperature setting will appear on the 
bottom left-hand of the screen in the blue window marked 

”Selected Temperature”

.  

The right-hand side of this screen shows the outside air temperature. 

Once the pool water temperature you want your iCool to cool to is selected, touch the 

“Start” 

button (next to the up down arrows). This takes you back to the 

Main Operating Screen.

 

If you did not need to use the Temperature Selection Screen and accepted 15ºC, then you will still be seeing 
the Main Operating Screen.

NOTE: The temperatures can also be displayed in Fahrenheit. This is explained on page 14 of this Manual.

STEP 3: Start the Water Pump.

Touch the 

”Start Pump”

 button. The pump will begin operating and water should begin circulating within 

a minute or so. 

Please note!

 When you touch the main buttons they change from 

”Start” buttons 

to 

”Stop” 

buttons 

and can then be used to 

Stop

 that function if required.

 

Water MUST be flowing correctly before you touch the “Start System” button.

 

The water flow is pre set to an optimum flow of between 100-200 litres or around 25-50 gallons per minute. This 

allows time for the heat exchangers to operate at maximum cooling efficiency and maintains the proper pressure.

Pool water is completely changed approximately every 10 to 15 minutes in a 6 person spa.

Do not touch

 

the

 

”Start System” 

button until you are sure that water is flowing smoothly.

 If water does not flow 

smoothly within two to three minutes, please check the plumbing, or if using an optional filtration system check that 

there is water in the filter housing and no air trapped. If your pump has a debris filter basket, check the basket.

If water does not flow smoothly after 2-3 minutes the system will sound 

an alarm and shut the pump off

. A red 

warning screen will appear with information about how to correct the water flow problem. 

STEP 2: Select the Required Temperature.

10

27

               Main Operating Screen 

 

 

Temperature Selection Screen

Start

Содержание TurboCool

Страница 1: ...Installation Operation Manual Turbo Cool Turbo Dual Temp 2012 Models...

Страница 2: ...onnections Page 9 Installing the Pump Page 9 Operating your TurboCool in Cold Mode Pages 10 to 12 Operating your TurboCool in Heat Mode Page 12 Detailed Function Description Page 13 Setting System Pre...

Страница 3: ...larly The main power switch is also part of the electrical safety circuit that can prevent the possibility of electric shock It is essential to test this safety system each time you use the iCool to m...

Страница 4: ...your spa pool is level with or above the pump then there is generally no need to prime the system as the water will flow by gravity to the pump If water does not flow after more than 2 minutes the iCo...

Страница 5: ...her and restart Normally settings above 8 C or or 45 F will not freeze the tanks in any conditions Safe Temperature Settings Following international safety reccomendations your iCool will not accept w...

Страница 6: ...pecial connection to 3 phase power whereas the TurboCool only requires single phase power This is new technology developed by iCool and has many advantages The Intelligent Control System Saves a Lot o...

Страница 7: ...e at least 500 mm apart This spacing can be reduced if they are installed front to back as shown in the illustration at bottom right Plumbing Requirements Just 2 standard 40mm PVC pool water pipes are...

Страница 8: ...ables that you must unplug in order to mount the back panel to a wall STEP 3 Unplug the 3 cables as shown so that the front can be separated from the rear panel STEP 4 The rear panel has several holes...

Страница 9: ...ct your TurboCool is to a wall box with an isolation switch however because the iCool also has an isolation safety switch and an earth leakage safety device built in you can also simply attach a power...

Страница 10: ...ake about 20 seconds and the screen will be black for about 10 seconds Touch the WELCOME screen anywhere and the Main Operating Screen will appear The status bar will flash white while the software lo...

Страница 11: ...ture Selection Screen and accepted 15 C then you will still be seeing the Main Operating Screen NOTE The temperatures can also be displayed in Fahrenheit This is explained on page 14 of this Manual ST...

Страница 12: ...T Do not operate the HEAT COLD switch while the iCool is running Turn off the main power first then change the switch position and turn the main power back on In HEAT mode the fans will immediately lo...

Страница 13: ...ing the Change Setting button this will take you to the Change Settings Screen From here you proceed as described on page 11 Lights Some iCool models have convenient area lighting which is very helpfu...

Страница 14: ...reference To return to the main operating screen touch the BACK 1 button 14 10 25 Systems Preferences Available System Preferences Touching the Home button will take you to a screen that will give yo...

Страница 15: ...screen illustrated below This screen allows you to see the countdown from a distance and also to control it in various convenient ways The current pool and outside temperature will also be displayed...

Страница 16: ...orised operators iCool Systems have attractive user interfaces this makes them easy to use but the downside is that untrained people often like to play with the colourful touchscreens This can upset a...

Страница 17: ...xplanation and advice on how to correct this If the iCool shuts down and displays a System Too Hot Red Warning Screen Your TurboCool is very powerful and can remove as much as 10 000 watts of heat per...

Страница 18: ...r Management System Digital 4 parameter Digital 4 parameter Standard Mounting Available Mounting Options Anti Vibration Feet Wall Frame Ceiling Frame Roller Wheels Anti Vibration Feet Wall Frame Ceili...