iCool TurboCool Скачать руководство пользователя страница 14

Page 14

“Back 1”

 

You can flip forward or backwards from page to page using the BACK button on the 

right-hand side of the help screens or you can return to be main help menu page at any time by 
touching the HOME button.

 

“All Stop”

There are several ways to stop the system and close it down. 

1. You can stop the cooling system only by touching the 

“Stop System”

 button, in this case 

the pump will continue to run, 

2. You can stop to pump at any time by touching the 

“Stop pump”

button. Stopping the 

pump while the System is running also automatically stops the Cooling (or Heating) System 
because it can not run safely without water. 

3 .Alternatively you can stop everything by touching the 

”All Stop”

.button 

If you use the

”All Stop”

 button  the fans may continue to run for a short time to cool the cabinet.

Display the pool temperature at full screen size.

If you touch the number in the pool temperature window 
on the Main Operation Screen for a few seconds the 
screen will change to a full-screen display of the pool 
temperature. (shown here at right)
This is useful if you wish to monitor the system from a 
distance.
The pre-set temperature and the outside temperature 
continue to be displayed in smaller windows for your 
reference.To return to the main operating screen touch 
the 

BACK 1

 button.

14

10

25

Systems Preferences

Available System Preferences

Touching the 

“Home” 

button will take you to a screen that will give you access to the 

SYSTEMS SETTINGS

 that allow you to customise certain settings to your preference.

Optimum settings are automatically selected

 

so there is normally no need to use this 

feature.

Main Cooling Fan Speed 

This allows you to set the main cooling fans to either 

Normal

 or 

Quiet

 mode. Generally you should always leave it in the 

Normal

  

mode which is fully automatic and allows the system to control the 

fan speed to give the very best efficiency.

Temperature Display scale. 

This can be set to either Centigrade or Fahrenheit and changes all 
of the displays throughout the entire system. The iCool normally 
reads in Centigrade as this is the world standard. It can convert the 
display to ºF if required, however due to rounding off calculations 
between Cº and Fº there may be minor differnces in the Fº display, 
however the system always holds the water temperature to within 1ªC.

Sound Level.

The 

Sound level

 

adjusts the sounds made when touching the screen and by the alarms. Normally it should be left 

on high to assist with settings and to make sure alarms are heard. There are three settings High, Medium and Low.  
A red dot indicates which setting is selected in each of the available settings. 

Stop

Stop

Содержание TurboCool

Страница 1: ...Installation Operation Manual Turbo Cool Turbo Dual Temp 2012 Models...

Страница 2: ...onnections Page 9 Installing the Pump Page 9 Operating your TurboCool in Cold Mode Pages 10 to 12 Operating your TurboCool in Heat Mode Page 12 Detailed Function Description Page 13 Setting System Pre...

Страница 3: ...larly The main power switch is also part of the electrical safety circuit that can prevent the possibility of electric shock It is essential to test this safety system each time you use the iCool to m...

Страница 4: ...your spa pool is level with or above the pump then there is generally no need to prime the system as the water will flow by gravity to the pump If water does not flow after more than 2 minutes the iCo...

Страница 5: ...her and restart Normally settings above 8 C or or 45 F will not freeze the tanks in any conditions Safe Temperature Settings Following international safety reccomendations your iCool will not accept w...

Страница 6: ...pecial connection to 3 phase power whereas the TurboCool only requires single phase power This is new technology developed by iCool and has many advantages The Intelligent Control System Saves a Lot o...

Страница 7: ...e at least 500 mm apart This spacing can be reduced if they are installed front to back as shown in the illustration at bottom right Plumbing Requirements Just 2 standard 40mm PVC pool water pipes are...

Страница 8: ...ables that you must unplug in order to mount the back panel to a wall STEP 3 Unplug the 3 cables as shown so that the front can be separated from the rear panel STEP 4 The rear panel has several holes...

Страница 9: ...ct your TurboCool is to a wall box with an isolation switch however because the iCool also has an isolation safety switch and an earth leakage safety device built in you can also simply attach a power...

Страница 10: ...ake about 20 seconds and the screen will be black for about 10 seconds Touch the WELCOME screen anywhere and the Main Operating Screen will appear The status bar will flash white while the software lo...

Страница 11: ...ture Selection Screen and accepted 15 C then you will still be seeing the Main Operating Screen NOTE The temperatures can also be displayed in Fahrenheit This is explained on page 14 of this Manual ST...

Страница 12: ...T Do not operate the HEAT COLD switch while the iCool is running Turn off the main power first then change the switch position and turn the main power back on In HEAT mode the fans will immediately lo...

Страница 13: ...ing the Change Setting button this will take you to the Change Settings Screen From here you proceed as described on page 11 Lights Some iCool models have convenient area lighting which is very helpfu...

Страница 14: ...reference To return to the main operating screen touch the BACK 1 button 14 10 25 Systems Preferences Available System Preferences Touching the Home button will take you to a screen that will give yo...

Страница 15: ...screen illustrated below This screen allows you to see the countdown from a distance and also to control it in various convenient ways The current pool and outside temperature will also be displayed...

Страница 16: ...orised operators iCool Systems have attractive user interfaces this makes them easy to use but the downside is that untrained people often like to play with the colourful touchscreens This can upset a...

Страница 17: ...xplanation and advice on how to correct this If the iCool shuts down and displays a System Too Hot Red Warning Screen Your TurboCool is very powerful and can remove as much as 10 000 watts of heat per...

Страница 18: ...r Management System Digital 4 parameter Digital 4 parameter Standard Mounting Available Mounting Options Anti Vibration Feet Wall Frame Ceiling Frame Roller Wheels Anti Vibration Feet Wall Frame Ceili...

Отзывы: