iCool LITE Скачать руководство пользователя страница 7

07

Owner’s manual for iCool Recovery Systems

Filter pump power outlet on all new models

If you plug the filter pump into any other electric outlet please be sure 

that the outlet you use is protected by an electrical safety device. 
No person should enter the pool unless an electrical safety device is 
provided. 

If there is no safety device then you must disconnect the pump before 
entering the pool.

iCool  filter  pumps  are  double  insulated  as  a  normal  precaution,  but 

it is not wise to completely trust this. Nothing is as safe as  a proper 
electrical safety device called an R.C.D.  Residual Current Device.  All 

iCools are fitted with and R.C.D.

The water hose connections shown below apply to all Compact and Lite models

CONNECT THIS HOSE TO THE TOP OF YOUR POOL

THIS HOSE SENDS THE CHILLED OR HEATED WATER BACK TO YOUR POOL

THIS HOSE COLLECTS WATER FROM YOUR 

POOL TO FEED IN THROUGH THE FILTER AND 

ON THE ICOOL TO BE CHILLED (OR HEATED*)

THIS HOSE SENDS FILTERED 

WATER TO THE ICOOL, TO BE 

CHILLED (OR HEATED*)

FROM THE POOL TO THE FILTER PUMP, FROM 

THE FILTER PUMP TO THE ICOOL, FROM THE 

ICOOL BACK TO THE POOL

*HEATING IS ONLY POSSIBLE WITH THOSE MODELS THAT HAVE THE HEATING FUNCTION

ONCE THE WATER IS FLOWING PLEASE UNSCREW THIS FITTING 

A SMALL AMOUNT TO ALLOW TRAPPED AIR TO ESCAPE. WHEN 

WATER APPEARS WITH NO BUBBLES SCREW IT TIGHT AGAIN

DIRECTION OF WATER FLOW

CONNECT THIS HOSE TO THE 

BOTTOM WATER FITTING OF 

YOUR ICOOL

CONNECT THIS HOSE TO THE BOTTOM 

OF YOUR POOL

STEP 3

WARNING

Only when your filter pump is connected to the power socket on 

your iCool, can your iCool provide proper electric shock protection

Содержание LITE

Страница 1: ...Owners Manual iCool Lite...

Страница 2: ......

Страница 3: ...rmful to athletes Because of the very small size the Lite uses a very compact stainless steel heat exchanger with silver connection seams Chlorine and Bromide are very corrosive and can quickly cause...

Страница 4: ...d insulation reduces these losses Good insulation will result in much faster cooling and save a lot of electricity HOLDING THE SET TEMPERATURE In normal conditions once your pool reaches your set temp...

Страница 5: ...come this quickly and easily ABOUT PUMPS Water flow through your iCool Lite is produced by a high quality long life circulating type pump that is fitted with a water filter to assist in keeping the wa...

Страница 6: ...er pump by plugging it directly in to a normal power outlet however you will need to activate the Disarm Flow Safety Sensor function to prevent your Lite shutting down due to a false No Water alarm ex...

Страница 7: ...d Lite models CONNECT THIS HOSE TO THE TOP OF YOUR POOL THIS HOSE SENDS THE CHILLED OR HEATED WATER BACK TO YOUR POOL THIS HOSE COLLECTS WATER FROM YOUR POOL TO FEED IN THROUGH THE FILTER AND ON THE I...

Страница 8: ...nd show a steady white light to indicate that the systems check was successful and that your iCool is ready to use Personal Logo Welcome Screens If you did not request a personal logo screen then the...

Страница 9: ...to heating or cooling depending on the temperature you set at the time you first switch it on The water is then automatically cooled or heated to your preset temperature and kept at that temperature...

Страница 10: ...y touching the change setting button this will take you to the change settings screen From here you proceed as described previously Note If you have the contrast model for safety reasons you cannot ch...

Страница 11: ...hrenheit and the sound level from the screen Main Cooling Fan Speed This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode w...

Страница 12: ...creen will begin to flash as with setting the clock Use the same up down and left right arrows to set the number of hours and minutes you wish to elapse before the system automatically shuts down The...

Страница 13: ...uching the display clock full screen button To go back to the previous screen touch the back 1 button Resets time to preset value in the single shot mode ready to start again by pressing the start but...

Страница 14: ...vering the topic you need assistance with the screen will change to a series of pages covering that subject Sample screens are illustrated below You can flip forward or backwards from page to page usi...

Страница 15: ...o normal when you restart it When your screen first starts up and the welcome screen appears a small warning notice may appear in the centre of the screen for one or two seconds referring to the inter...

Страница 16: ...tion to this service you will be pleased to know that your iCool is of a modern modular design which means that most components can be easily replaced in the field and often by the owner UNDERSTANDING...

Страница 17: ...rage 30 Litres per min average Maximum Alternative Pump Flow 100 Litres per min 500 Watts 100 Litres per min 500 Watts 150 Litres per min 750 Watts Main Power Plug 3 Pin Heavy Duty 3 Pin Heavy Duty 3...

Страница 18: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com...