iCool LITE Скачать руководство пользователя страница 12

12

iCool Lite

Temperature Limitations

Because of the dangers of hypothermia in the case of an unattended 
athlete using the pool, your system will not allow you to set 

temperatures below 5°C/40°F. If the model you are using is the contrast 

model which also provides heating for contrast therapy you cannot set 

the  temperature  above  45°C/112°F  because  of  the  risk  of  scalding. 

These temperature limits have been set after wide consultation with 
the sporting industry around the world. 

There are no demonstrated benefits in using water temperature lower 

than 5°C or above 45°C and therefore the risk of doing so is not justified.

Timing Functions

Your iCool offers a number of very useful timing 

functions including a real-time clock, a countdown 

timer to time recovery and training sessions and a 
timer to shut down the system automatically at a 
predetermined time after use.  To set up and use 
these functions touch the timer function button 
on the home screen.  You can reach this screen by 

using the back 1 button or the home button.

In order to use the auto shut down function you first 

need to set the time of day on the built-in clock.  

To set the clock touch the set main clock button on 

the timing functions screen and the time setting display on the bottom 
right of the screen will begin flashing. You must set it while one of the 
numbers is flashing by using the up down and left right keys. Once you 
stop using these keys for more than a few seconds  the display will 
stop flashing and the time showing is set into the system and the clock 
begins operating.

The iCool clock operates in the universal 24-hour time style.

Automatic System Shutdown Timer  

You  can preset your iCool to shut down at any time 

up to five hours in the future. This is very convenient 

for coaches and specialists who may want to leave 
the training area early but want to make sure that 
the system is not left running needlessly. To set 
this time, touch the set shut down button and the 

clock digits on the bottom right of the screen will begin to flash as 
with setting the clock. Use the same up down and left right arrows to 
set the number of hours and minutes you wish to elapse before the 
system automatically shuts down. The system automatically begins 

Time Setting Screen

11:25

TIMER FUNCTIONS

SET MAIN CLOCK

the countdown and will stop when the time you set reaches zero. The 
time remaining before shutdown is displayed on the main clock display 
screen.

As the same arrows are used to set all three time functions, to avoid 

confusion, a red dot appears next to be button of the function being set.

Recovery Session Timer Functions 

A very popular and useful feature of your iCool is the session countdown 
timer.

This allows you to accurately control the immersion times of athletes 
and to repeat those times as often as needed. This is an essential 
part of successful cryo recovery therapy and is just as important as 
maintaining accurate and consistent temperatures, which of course 
your iCool does perfectly.

The session timer is set up from the main time setting screen by 
touching the set countdown button. The numbers on the setting screen 

in  the  bottom  right-hand  corner  will  begin  to  flash  and  you  can  use 

the left, right and up, down arrows to change the time in minutes and 
seconds. Once you have set the time you want your athletes to remain 

in the bath, touching the display countdown full-screen button will take 

you to the screen illustrated on the next page. This screen allows you 

to see the countdown from a distance and also to control it in various 
convenient ways. The current pool temperature and the outside 
temperature will also be displayed.

The count down can be set for once only, or it can repeat automatically 
as many times as you like. This is particularly convenient if you have a 
number of athletes using the same pool at the same time. The system 

beeps for each of the last five seconds at the end of each countdown 

to warn the athletes to get ready to get either in or out of the pool 
and pauses for several seconds to allow the changeover before the 
countdown begins again (if it is set in the repeat mode).

SET SHUT DOWN

DISPLAY 

COUNTDOWN

FULL

SCREEN

SET COUNT DOWN

DISPLAY COUNTDOWN

DOWN

UP

RIGHT

LEFT

Содержание LITE

Страница 1: ...Owners Manual iCool Lite...

Страница 2: ......

Страница 3: ...rmful to athletes Because of the very small size the Lite uses a very compact stainless steel heat exchanger with silver connection seams Chlorine and Bromide are very corrosive and can quickly cause...

Страница 4: ...d insulation reduces these losses Good insulation will result in much faster cooling and save a lot of electricity HOLDING THE SET TEMPERATURE In normal conditions once your pool reaches your set temp...

Страница 5: ...come this quickly and easily ABOUT PUMPS Water flow through your iCool Lite is produced by a high quality long life circulating type pump that is fitted with a water filter to assist in keeping the wa...

Страница 6: ...er pump by plugging it directly in to a normal power outlet however you will need to activate the Disarm Flow Safety Sensor function to prevent your Lite shutting down due to a false No Water alarm ex...

Страница 7: ...d Lite models CONNECT THIS HOSE TO THE TOP OF YOUR POOL THIS HOSE SENDS THE CHILLED OR HEATED WATER BACK TO YOUR POOL THIS HOSE COLLECTS WATER FROM YOUR POOL TO FEED IN THROUGH THE FILTER AND ON THE I...

Страница 8: ...nd show a steady white light to indicate that the systems check was successful and that your iCool is ready to use Personal Logo Welcome Screens If you did not request a personal logo screen then the...

Страница 9: ...to heating or cooling depending on the temperature you set at the time you first switch it on The water is then automatically cooled or heated to your preset temperature and kept at that temperature...

Страница 10: ...y touching the change setting button this will take you to the change settings screen From here you proceed as described previously Note If you have the contrast model for safety reasons you cannot ch...

Страница 11: ...hrenheit and the sound level from the screen Main Cooling Fan Speed This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode w...

Страница 12: ...creen will begin to flash as with setting the clock Use the same up down and left right arrows to set the number of hours and minutes you wish to elapse before the system automatically shuts down The...

Страница 13: ...uching the display clock full screen button To go back to the previous screen touch the back 1 button Resets time to preset value in the single shot mode ready to start again by pressing the start but...

Страница 14: ...vering the topic you need assistance with the screen will change to a series of pages covering that subject Sample screens are illustrated below You can flip forward or backwards from page to page usi...

Страница 15: ...o normal when you restart it When your screen first starts up and the welcome screen appears a small warning notice may appear in the centre of the screen for one or two seconds referring to the inter...

Страница 16: ...tion to this service you will be pleased to know that your iCool is of a modern modular design which means that most components can be easily replaced in the field and often by the owner UNDERSTANDING...

Страница 17: ...rage 30 Litres per min average Maximum Alternative Pump Flow 100 Litres per min 500 Watts 100 Litres per min 500 Watts 150 Litres per min 750 Watts Main Power Plug 3 Pin Heavy Duty 3 Pin Heavy Duty 3...

Страница 18: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com...