OPEN RAMPDOWN DISTANCE
This setting is used to change the point where the door begins to decelerate
to slow speed as it approaches the Open Limit. The user can choose between
auto (which is configured by the system) or the desired number of shaft rotations
(between 0.5 turns and 3 turns in half rotation increments).
The Factory default setting for this feature is AUTO. This should not be changed
unless recommended by Pulse Technical Support.
CLOSE RAMPDOWN
DISTANCE
This setting is used to change the point where the door begins to decelerate
to slow speed as it approaches the Close Limit. The user can choose between
auto (which is configured by the system) or the desired number of shaft rotations
(between 0.5 turns and 3 turns in half rotation increments).
The Factory setting for this feature is AUTO. This should not be changed unless
recommended by Pulse Technical Support.
OPEN SLOW SPEED
When the door is approaching open limit and decelerates to slow speed before
the stop (Soft Stop), added force/speed may be required to complete opening.
While this is indcative of an improperly balanced door, this feature can be used
to compensate. This setting should only be changed from the NORMAL to the
HIGH setting if door becomes unbalanced over time and does not completely
travel to Open limit. If it is a new installation, changing the spring tension for
proper balance is a required first step. Factory default is ‘NORMAL’.
CLOSE SLOW SPEED
When the door is approaching Close Limit and decelerates to slow speed before
the stop (Soft Stop), added force/speed may be required to complete closing.
While this is indcative of an improperly balanced door, this feature can be
used to temporarily compensate. This setting should only be changed from the
NORMAL to the HIGH setting if door
becomes
unbalanced over time and does
not completely travel to Close limit. If it is a new installation, changing the spring
tension for proper balance is a required first step. Factory default is ‘NORMAL’.
PWM FREQUENCY
This Setting allows the user to change the operating frequency for the motor
between 2.4 kHz, 12kHz and 20kHz. Certain frequencies can interfere with third-
party accessories, and adjustment may be necessary. Factory default is set to
12kHz. Do not alter this setting unless advised by Technical Support.
Note that if this setting is turned to OFF, Push & Hold to Close protocol (constant
pressure) will be initiated.
OUTPUT RELAY OPTIONS
The Output Relay is used for signalling/interlocking with other devices such as
a dock leveller, security equipment, other doors, etc. There is one NO and one
NC contact available that can be energized at either the open or closed limit, or
between limits, as chosen by the user in this setting.
The Factory setting for this feature is ENERGIZED WHEN OPEN.