background image

15

14

www.iconico.es

User manual WC3

Water pressure adjustment

Auto function

Auto cleaning sequence

Temperature adjustments

Spray nozzle position adjustment

Energy saver

• Press [+] or [-] button when it is under function of rear cleaning or front cleaning, the 

indicator light will be on showing current the water temperature level, adjust the water 

pressure by 3 levels.

• The automatic default setting is middle level for water volume, nozzle position, water 

temperature, air temperature, seat temperature; is turned off for the massage function. 

• Short press [Auto rear cleaning] or [Auto front cleaning] button to start rear or front 

cleaning automatically. The user can adjust the water pressure, nozzle position and 

temperature level as per requirement, the memory keep the last setting when the user 

presses the Auto button, cleaning and drying function is  activated automatically.

• The Auto function mode will be off if the user presses other buttons during the 

operation and will shift to the pressed function.

• Press [Air temperature] button, the indicator light will light up the displayed air 

temperature level, continue to press the [Air temperature] button to adjust the air 

temperature. It will be neutral level when the indicator light is off.

Auto rear cleaning

Rear cleaning 40s

Auto front cleaning

Front cleaning 40s

Dry 180s

Front cleaning 20s
Dry 180s

Automatic stop

Massage cleaning 30s

Automatic stop

• Press [   ] or [   ] button when it is under function of rear cleaning or front cleaning, the 

indicator light will be on showing the current nozzle position, adjust the nozzle position 

by 3 levels.

Keep pressing [Stop] button for more than 3s to enter the energy saving mode, the 

indicator light will be off and the energy saving light will be on. Keep pressing [Stop] 

button again for more than 3s to exit energy saving mode, the indicator light will be on 

and the energy saving light will be off.

 

Under the energy saving mode, seat temperature is low (level 1) .

Note:

 If the seat temperature before energy saving is neutral it will continue as neutral during the 

energy saving mode.

 

• Energy saving mode will be suspended and go to function mode if someone uses the 

seat. The seat will start to heat immediately. The energy saving mode will be restored 

after the person leaves the seat.

  PRESSURE

POSITION

REAR/MOVE

FRONT/MOVE

DRY

Nozzle

        STOP

HOLD TO ECO

Rear cleaning 20s

Massage cleaning 30s

Air temperature adjustment: 

Water temperature adjustment: 

• Press the [Water temperature] button, the indicator light will light up the displayed 

water temperature position, continue to press the [Water temperature] button to adjust 

the water temperature. The indicator light will be neutral when the indicator light is off. 

Note:

 when the neutral level is selected, the temperature is 10±2.5°C. When the water temperature 

is higher than 10 °C, it will not be heated; when it is lower than 10 °C, it will heated; and the 
temperature of the outlet water will be controlled around 10 °C.

 - Only for the toilet with auto flush function)

Energy saving:

Remark:

Содержание WC 3

Страница 1: ...1 User manual WC3 WC 3 User manual www iconico es hola iconico es Elements for architecture ...

Страница 2: ...3 2 www iconico es User manual WC3 Please read carefully the instrucctions of this manual before installation and keep it available for future maintenance or reference ...

Страница 3: ...g 10 Product specifications 11 Warranty 7 Daily maintenance 9 Common fault diagnosis 4 Function description of main unit buttons 5 Remote 6 Remote operation procedures 3 Parts identification 1 Safety instructions 2 Grounding instructions 5 1 Remote control installation 5 2 Remote battery installation ...

Страница 4: ...for its intended use as described in this manual Do not use attachments not recommended by the manufacturer Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water If the electric cord is damaged it must be replaced by the manufacturer its service center or equivalent specialist Keep the cord away from heated...

Страница 5: ... capable of supporting a minimum of 10A It is recommended to unplug the unit during thunderstorms to prevent electrical damage Do not stand on product seat or seat cover Do not lean against the seat cover when using the product This product is equipped with a soft closing seat cover Do not push the toilet seat closed or damage may occur Do not use any caustic chemicals to clean this product Exposu...

Страница 6: ...cleaning process press Rear Move button to activate the rear massage cleaning function Press Stop button to stop cleaning 2 While not sitting on the unit short press Rear Move button the wand will extend outwards to allow access for maintenance cleaning After cleaning is completed short press Stop button to retract wand Note 1 In working mode the power light is on and Energy Saver light is off In ...

Страница 7: ...he person can reach the remote while seating on the toilet 1 Put the batteries into the remote control and cover it 2 Place the remote control into the hanger PRESSURE POSITION REAR MOVE FRONT M OVE STOP HOLD TO ECO DRY 5 2 Remote battery installation 6 Remote operation procedures Rear cleaning Front cleaning Dry operation Press Rear cleaning massage button the indicator light is on showing curren...

Страница 8: ...ess or button when it is under function of rear cleaning or front cleaning the indicator light will be on showing the current nozzle position adjust the nozzle position by 3 levels Keep pressing Stop button for more than 3s to enter the energy saving mode the indicator light will be off and the energy saving light will be on Keep pressing Stop button again for more than 3s to exit energy saving mo...

Страница 9: ...tion will stop 3s after the user leaves The deodorizing function will be off during drying operation Only for the toilets with auto deodoriing function this function is the default when the toilet is power on Remark With quite mode off the buzzer will beep when the user presses one button which means the main unit receives the signal and conduct the operation accordingly If the buzzer doesn t soun...

Страница 10: ...onnect the power before maintenance 2 Use only a soft damp cloth to clean Avoid using harsh chemicals Filter maintenance If the spray performance is poor under normal conditions 1 Turn off the water supply at the ball valve switch and disconnect water inlet hose General maintenance When the electronic bidet is working abnormally and needs to be repaired the following steps must be taken first 1 Dr...

Страница 11: ...connected to the unit and is not kinked or bent Ball valve switch is notfully open Turn the ball valve switch ON Inlet filter is blocked Remove and clean the filter as outlined in the section Filter Maintenance High or low water temperature The water temperature is set too high or too low If the water temperature is too hot or too cold adjust the temperature on the remote control High or low seat ...

Страница 12: ...V 50 60Hz Rated power 1080 1130W Protection class Main unit IPX4 Water pressure range Minimum water pressure 0 08MPa Hydrostatic pressure Maximum water pressure 0 8MPa Hydrostatic pressure Toilet Water consumption Full flush 6 0L Half flush 4 0L Flush type Washdown Horizontal outlet Outlet height 212mm Outlet outside diameter 102mm Waster outlet P trap Cleaning device Heating power 1600W peak Wate...

Страница 13: ...sing date covering the free repair of problems arising from manufacturing defects whenever the toilet has been installed and used following the indications in the provided user s manual If the product starts not working properly within the warranty period please contact your nearest service center A clear copy of the original seller s invoice must be presented to enjoy the free service offered byt...

Страница 14: ...26 www iconico es www iconico es hola iconico es Elements for architecture ...

Отзывы: