background image

19

18

www.iconico.es

User manual WC3

7. Daily maintenance

Main unit maintenance

Spray nozzle maintenance

3. Use only a soft, damp cloth to clean. 

Avoid using harsh chemicals.  

DO NOT pull the nozzle housing outward or 

inward to prevent damage of the nozzle and 

motor. 

4. Once cleaning is completed, re-install 

the nozzle to the nozzle housing. Press 

the [Stop] button on the main unit/remote 

control to return the nozzle rod to its normal 

position.

Note:

 In this state, the nozzle rod will return 

to its normal position if sitting on the unit or 

no operation for 10 minutes.

3. Safety self-inspection

• After cleaning, re-connect the toilet with 

the power supply. 

1. While not sitting on the unit, short 

press the [Rear/Move] Button on the 

main unit, the spray nozzle will extend 

outward and water will flow out.

2. The spray nozzle can be removed 

and cleaned separately. After the spray 

nozzle extends outward, hold the nozzle 

housing with one hand, remove the 

nozzle itself by gently pulling it with the 

other hand.

1. Disconnect the power before 

maintenance.

2. Use only a soft, damp cloth to clean. 

Avoid using harsh chemicals.

Filter maintenance

If the spray performance is poor 
under normal conditions:

 

1. Turn off the water supply at the ball valve 

switch and disconnect water inlet hose.

General maintenance

When the electronic bidet is working 

abnormally and needs to be repaired, the 

following steps must be taken first. 

1. Drain the water inside the bidet:

• Hold the [Stop] button and press 

the [Water temperature] button on the 

remote control.

2. Turn off water and power supply:

• Turn off ball valve switch and disconnect 

power.

3. Empty residual water in the tank:

• Remove fixing screws of bidet and 

then lift the bidet up (refer to installation 

manual), remove the drain plug and 

ensure water in the tank is completely 

emptied.

2. Remove the filter.

3. Clean out filter under running water.

4. Re-install the filter, re-connect water inlet 

    hose and then turn on water supply.

Note:

 

DO NOT put the bidet upside down or on its 

sides before emptying all water in the tank. 

Once water is emptied, reinstall the drain 

plug.

Unscrew the drain plug with slotted screwdriver

4. Disconnect water inlet hose and coupler 

before the next step of maintenance

Содержание WC 3

Страница 1: ...1 User manual WC3 WC 3 User manual www iconico es hola iconico es Elements for architecture ...

Страница 2: ...3 2 www iconico es User manual WC3 Please read carefully the instrucctions of this manual before installation and keep it available for future maintenance or reference ...

Страница 3: ...g 10 Product specifications 11 Warranty 7 Daily maintenance 9 Common fault diagnosis 4 Function description of main unit buttons 5 Remote 6 Remote operation procedures 3 Parts identification 1 Safety instructions 2 Grounding instructions 5 1 Remote control installation 5 2 Remote battery installation ...

Страница 4: ...for its intended use as described in this manual Do not use attachments not recommended by the manufacturer Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water If the electric cord is damaged it must be replaced by the manufacturer its service center or equivalent specialist Keep the cord away from heated...

Страница 5: ... capable of supporting a minimum of 10A It is recommended to unplug the unit during thunderstorms to prevent electrical damage Do not stand on product seat or seat cover Do not lean against the seat cover when using the product This product is equipped with a soft closing seat cover Do not push the toilet seat closed or damage may occur Do not use any caustic chemicals to clean this product Exposu...

Страница 6: ...cleaning process press Rear Move button to activate the rear massage cleaning function Press Stop button to stop cleaning 2 While not sitting on the unit short press Rear Move button the wand will extend outwards to allow access for maintenance cleaning After cleaning is completed short press Stop button to retract wand Note 1 In working mode the power light is on and Energy Saver light is off In ...

Страница 7: ...he person can reach the remote while seating on the toilet 1 Put the batteries into the remote control and cover it 2 Place the remote control into the hanger PRESSURE POSITION REAR MOVE FRONT M OVE STOP HOLD TO ECO DRY 5 2 Remote battery installation 6 Remote operation procedures Rear cleaning Front cleaning Dry operation Press Rear cleaning massage button the indicator light is on showing curren...

Страница 8: ...ess or button when it is under function of rear cleaning or front cleaning the indicator light will be on showing the current nozzle position adjust the nozzle position by 3 levels Keep pressing Stop button for more than 3s to enter the energy saving mode the indicator light will be off and the energy saving light will be on Keep pressing Stop button again for more than 3s to exit energy saving mo...

Страница 9: ...tion will stop 3s after the user leaves The deodorizing function will be off during drying operation Only for the toilets with auto deodoriing function this function is the default when the toilet is power on Remark With quite mode off the buzzer will beep when the user presses one button which means the main unit receives the signal and conduct the operation accordingly If the buzzer doesn t soun...

Страница 10: ...onnect the power before maintenance 2 Use only a soft damp cloth to clean Avoid using harsh chemicals Filter maintenance If the spray performance is poor under normal conditions 1 Turn off the water supply at the ball valve switch and disconnect water inlet hose General maintenance When the electronic bidet is working abnormally and needs to be repaired the following steps must be taken first 1 Dr...

Страница 11: ...connected to the unit and is not kinked or bent Ball valve switch is notfully open Turn the ball valve switch ON Inlet filter is blocked Remove and clean the filter as outlined in the section Filter Maintenance High or low water temperature The water temperature is set too high or too low If the water temperature is too hot or too cold adjust the temperature on the remote control High or low seat ...

Страница 12: ...V 50 60Hz Rated power 1080 1130W Protection class Main unit IPX4 Water pressure range Minimum water pressure 0 08MPa Hydrostatic pressure Maximum water pressure 0 8MPa Hydrostatic pressure Toilet Water consumption Full flush 6 0L Half flush 4 0L Flush type Washdown Horizontal outlet Outlet height 212mm Outlet outside diameter 102mm Waster outlet P trap Cleaning device Heating power 1600W peak Wate...

Страница 13: ...sing date covering the free repair of problems arising from manufacturing defects whenever the toilet has been installed and used following the indications in the provided user s manual If the product starts not working properly within the warranty period please contact your nearest service center A clear copy of the original seller s invoice must be presented to enjoy the free service offered byt...

Страница 14: ...26 www iconico es www iconico es hola iconico es Elements for architecture ...

Отзывы: