2
SETTING UP THE TRANSCEIVERS
2-4
Multicast mode operation
■
Registering a transceiver to the RoIP Gateway
(
☞
Continued on the next page)
1
Open the Bridge Connection screen.
(Bridge Connection Settings > Bridge Connection)
2
In [Bridge Connection], confirm the connection Source (Example: EXT1), the Bridge Connection
Destination (Custom Bridge Connection), and the IP address of the destination (239.255.255.1), then
click <Apply>.
w
Enter
e
Click
q
Confirm
•
The confi rmation dialogs are displayed. Click <OK> twice to apply them.
L
When the bridge connection is set, the Connection Port setting is deleted from the “Destination Settings”
(Destination settings > Destination Settings)
3
In [AMBE+2 Vocoder Assignment], select the Voice Protocol and AMBE+2 Vocoder Assignment, and
then click <Apply>.
q
Select
w
Click
L
By default, all of the 4 Internal AMBE+2 vocoders are assigned to the digital transceivers. Disable one of the
internal AMBE+2 vocoders to assign it to the EXT1 port.
L
If you need an additional AMBE+2 vocoder, an optional CT-24
digital
voice
converter
is required.