background image

11

2

INSTALLATION AND CONNECTIONS

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

q

  Remove the four screws from the corners of the 

EX-3187.

w

  Unscrew the Sealing Nut from the Sealing tube.

e

  Unscrew the inside Nut from the Sealing tube.

r

  Remove  the  five  connectors  from  the  board,  as 

shown below.

t

  Remove the cable from the EX-3187’s case.

y

  After installing the removed cable at the desired 

place, replace the connectors and the Sealing Nut.

 Removing or connecting the EX-3187’s cable

Sealing tube

Sealing Nut

Washer

Inside nut

Ferrite EMI filter

Ferrite EMI filter

CAUTION: 

NEVER cut the display cable or display 

extension cable.

NOTE: About Display Cable
The Display cable can also be removed to install 
it through a hole in a wall. After installing the cable 
through the hole, replace the Sealing Nut in the 
same order as described to the left.

To  install  the  display  cable  though  a  hole  in  a  wall 
where as the display connector cannot pass through 
the hole, remove the cable from the EX-3187 or the 
Display unit. Then pass it through the hole, as shown 
below.

BE CAREFUL! The EX-3187 meets IPX4 require-
ment for splash resistant when the connecting the 
connection cables. However, once the unit has been 
opened, splash resistance cannot be guaranteed.

Содержание MarineCommander MXP-5000

Страница 1: ...his device complies with Part 15 of the FCC Rules Opera tion is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference...

Страница 2: ...4 2 Spring washers M4 2 FCC INFORMATION FOR CLASS A UNINTENTIONAL RADIATORS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the F...

Страница 3: ...LATION AND CONNECTIONS 6 11 Connection 6 Mounting the Main unit 7 Power source requirement 7 Ground connection 7 Installing the Display unit 8 Front cover attachment 10 Bolt cap attachment 10 Removing...

Страница 4: ...ection is made after cutting the Main unit may be damaged R WARNING NEVER open the bottom cover of the Main unit There are no user adjustment points This may result in an electric shock and incorrect...

Страница 5: ...BLACK BOX CONNECTORS Connector 1 to 3 Connect a black box unit such as an MXR 5000R T Radar unit an MXF 5000 Fish finder unit or another MXP 5000 Main unit Connector 4 Not used If you connect an MXR 5...

Страница 6: ...to the MOB point Position and bearing data are neces sary Hold down MOB for 3 seconds to cancel the func tion e RANGE UP DOWN SWITCHES Push or to set a suitable screen range r FOCUS DISPLAY LAYOUT SW...

Страница 7: ...een Quick Menu 2 includes the GAIN SEA RAIN Radar TX menu and Heading line OFF functions On the Sounder screen Quick Menu 2 includes the GAIN 50kHz GAIN 200kHz STC 50kHz and STC 200kHz control func ti...

Страница 8: ...is invalid the position data is shown in red for 1 minute After 1 minute has passed invalid data will appear ePALETTE2 Shows various information Default COG Shows your vessel s course over ground T s...

Страница 9: ...nit 1FISH FINDER ICON Display as an animation when a companion Icom fish finder is connected and operating Appears but not as an animation when the fish finder is connected but not operating An X appe...

Страница 10: ...round 12 V 24 V battery White Black Green Thinner Black KEEP the terminal guard attached after connecting the cable NOTE Use crimp or solder terminals for the wire connections Solder Crimp Radar unit...

Страница 11: ...3 14 15 16 17 18 19 20 21 Power source requirement CAUTION Before connecting the DC power cable check the following important items Make sure Output voltage of the power source is 12 V 24 V DC DC powe...

Страница 12: ...fter installation Select a location which can support the weight of the display unit DO NOT select areas subject to extreme heat cold vibrations or direct sunlight D Mounting The mounting bracket supp...

Страница 13: ...he four bolts from the four corners of the display unit w Carefully cut a hole in the instrument panel or wherever you plan to mount the display unit e Drill four holes for the mounting screw r Slide...

Страница 14: ...ront cover attachment The supplied front cover can be attached to the front of the display unit Front cover Bolt cap attachment The supplied bolt caps can be attached to the four corner bolts to prote...

Страница 15: ...ide nut Ferrite EMI filter Ferrite EMI filter CAUTION NEVER cut the display cable or display extension cable NOTE About Display Cable The Display cable can also be removed to install it through a hole...

Страница 16: ...o the MarineCommander MXA 5000 ais receiver Allows you to receive other vessel s information such as the vessel name MMSI code vessel type position data speed course destination and more MXG 5000 gps...

Страница 17: ...consumption Less than 1 0 A at maximum brightness Usable temperature range 20 C to 60 C 4 F to 140 F Dimensions without Bracket 386 W 274 H 69 2 D mm 15 2 W 10 8 H 2 7 D in with Bracket 404 W 299 H 10...

Страница 18: ...IS 1 IN Grey Black 1 15 AIS COMMON Common line for AIS 2 Port 4 VHF Orange Black 2 19 DSC IN Input level Less than 2 mA with 2 V applied DSC DSE PICOA Connects to the NMEA input output con nector of a...

Страница 19: ...15 MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21...

Страница 20: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 6755H 1EX Printed in Japan 2011 Icom Inc...

Отзывы: