DSC OPERATION
DSC Loop Test
D
The DSC loop test function sends transmit DSC signals to
the receive AF circuit to compare and check the TX and RX
signals at the AF level.
Enter “DSC LOOP TEST” in the DSC Settings menu.
q
MENU
➪
DSC Settings
➪
DSC Loop Test
(Push [MENU]) (Rotate Dial, then push [ENT].)
Push [ENT] to start the DSC loop test.
w
•Push[BACK]tocancelandreturntotheDSCSettingsmenu.
•WhenthetransmitDSCandreceiveDSCsignalsarematched,
“OK” appears.
Push [EXIT] to return to the normal operating mode.
e
If “NG” appears in step
w
, either or both TX and RX DSC
circuits has a problem. In that case, you will have to send
the transceiver to your nearest dealer for repair.