![Icom IC-M802 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/icom/ic-m802/ic-m802_instruction-manual_611284070.webp)
62
13
CONNECTION AND INSTALLATION
2001 NEW
D
Internal fuse replacement
q
Unscrew 8 screws from the top cover, then remove
the cover.
w
Unscrew 8 screws from the PA shield cover, then
open the cover.
• The cooling fan is fixed with the PA shield cover.
• Move the coaxial cable as shown in the diagram.
• Be careful the cooling fan power cables are still con-
nected.
Coaxial
cable
e
Replace the circuitry fuse as shown in the diagram
below.
• Use the supplied FGB 5 A fuse (glass tube type).
r
Attach the PA shield cover, coaxial cable and top
cover to their original position.
■
Fuse replacement
The transceiver has 2 fuses (2 types) to protect in-
ternal circuitry, 1 fuse for the fuse holder on the DC
power cable and 1 for inside. If the transceiver stops
functioning, check the fuses below.
• DC power cable ����������� FGB 30 A
• Circuitry fuse ������������ FGB 5 A
CAUTION:
DISCONNECT
the DC power cable from
the transceiver when changing a fuse.
D
Line fuse replacement
FGB 30 A
2001 NEW
Содержание IC-M802
Страница 1: ...MF HF MARINE TRANSCEIVER iM802 INSTRUCTION MANUAL ...
Страница 75: ...16 67 TEMPLATE 16 15 92 mm 35 8 110 mm 411 32 204 mm 8 1 32 220 mm 8 21 32 4 R11 Remote controller RC 25 ...
Страница 76: ......
Страница 77: ...69 16 TEMPLATE 16 92 mm 35 8 110 mm 411 32 4 R11 110 mm 4 11 32 92 mm 3 5 8 Speaker SP 24 Cut here ...
Страница 78: ......
Страница 79: ...71 MEMO 71 ...
Страница 80: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 7096H 1US Printed in Japan 2013 Icom Inc ...