INSTALLATION AND CONNECTIONS
■
Power supply connections
When operating the transceiver with AC power, use a
power supply with 13.8 V DC output and a capacity of
at least 23 Amps.
Refer to the diagrams below.
CAUTION:
Before connecting the DC power
cable, check the following important items.
Make sure:
• The [POWER] switch is OFF.
• Output voltage of the power source is 12–15 V
when you use a non-Icom power supply.
• DC power cable polarity is correct.
Red : Positive
+
terminal
Black : Negative
_
terminal
q
w
Transceiver
PS-126
AC cable
AC outlet
To [DC 13.8V]
DC power cable
D
Connecting to the PS-126 DC POWER SUPPLY
D
Connecting to a non-Icom DC POWER SUPPLY
■
Connecting to a DC power supply
+
_
q
w
Supplied DC power cable
AC cable
AC outlet
Transceiver
To [GND]
A DC power supply
13.8 V;
at least 23 A
Red
Black
To [DC 13.8V]
To [DC 13.8V]
For European versions
Transceiver
Connect to
power supply
Ground
Ground
To disconnect
To disconnect
When you install the ferrite
EMI filter, make sure the ca-
bles at the top of the loop are
parallel to each other.