38
9
SET MODES
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
•
User remote control unit
The circuit illustrated below is for reference only.
D
Voltage indication
The voltage of the battery is displayed at power ON. This dis-
play can be turned ON or OFF.
• VLt.OF
: The battery voltage display is skipped.
• VLt.On
: The battery voltage is displayed at power ON.
D
Battery protection
When the battery voltage decreases, the Battery Protection
function automatically turns OFF the transceiver.
Select the function option according to your battery type.
• bAt.OF
: Turns OFF the function. Select when you use the BP-263
battery case.
• bAt.nm
: Select when you use the BP-264 Ni-MH battery pack.
• bAt.LI
: Select when you use the BP-265 Li-Ion battery pack.
NOTE: BE SURE to select an appropriate option accord-
ing to your battery type.
D
Auto low power
Turns the Automatic Low-power function ON or OFF.
When the temperature goes below 0°C, the function automat-
ically sets the output power to low.
In that case, the transmit power options (Hi or Mid) are also
disabled.
• ALP.OF : Turns OFF the function.
• ALP.On : The output power is automatically set to low when the
temperature goes below 0°C.
2.7 k
Ω
6.8 k
Ω
15 k
Ω
33 k
Ω
+
–
S1
S2
S3
S4
to the [SP] jack
GND
SP
REMOTE
Rated input
700 mW (8
Ω
)
EXTERNAL SPEAKER
3.5(d) mm
>
‗