Cmd. Sub cmd.
Data
Description
07
00 or 01
Read the Overflow status
( 00=OVF indicator is OFF, 01=OVF indicator is ON)
11
0000 ~ 0255 Read the PO meter level
(0000=0% to 0143=50% to 212=100%)
12
0000 ~ 0255 Read SWR meter level
( 0000=SWR1.0, 0048=SWR1.5,
0080=SWR2.0, 0120=SWR3.0)
13
0000 ~ 0255 Read ALC meter level
(0000=Min. to 0120=Max.)
14
0000 ~ 0255 Read COMP meter level
(0000=0 dB, 0130=15 dB, 0241=30 dB)
15
0000 ~ 0255 Read Vd meter level
(0000=0 V, 0151=10 V, 0211=16 V)
16
0000 ~ 0255 Read Id meter level
( 0000=0A, 0077=10A, 0165=20A, 0241=30A)
16* 02
00
Preamp OFF
01
Preamp 1 ON
02
Preamp 2 ON
12
01 ~ 03
Set the AGC time constant
(01=FAST, 02=MID, 03=SLOW)
22
00 or 01
Set the Noise blanker
(00=OFF, 01=ON)
32
00
Audio peak filter OFF
01
Audio peak filter WIDE ON
(320 Hz is selected when SHARP APF is set)
02
Audio peak filter MID ON
(160 Hz is selected when SHARP APF is set)
03
Audio peak filter NAR ON
(80 Hz is selected when SHARP APF is set)
40
00 or 01
Set the Noise reduction
(00=OFF, 01=ON)
41
00 or 01
Set the Auto Notch function
(00=OFF, 01=ON)
42
00 or 01
Set the Repeater tone
(00=OFF, 01=ON)
43
00 or 01
Set the Tone squelch
(00=OFF, 01=ON)
44
00 or 01
Set the Speech compressor
(00=OFF, 01=ON)
45
00 or 01
Set the Monitor [MONI] function
(00=OFF, 01=ON)
46
00 or 01
Set the VOX function
(00=OFF, 01=ON)
47
00
BK-IN function OFF
01
Semi BK-IN function ON
02
Full BK-IN function ON
48
00 or 01
Set the Manual Notch function
(00=OFF, 01=ON)
4E
00 or 01
Set the DIGI-SEL function
(00=OFF, 01=ON)
4F
00 or 01
Set the Twin peak filter
(00=OFF, 01=ON)
( Can be turned ON only when Mark and Shift
are set to 2125 Hz and 170 Hz, respectively)
50
00 or 01
Set the Dial lock function
(00=OFF, 01=ON)
53*
2
00 or 01
Set the ANT-RX I/O
(00=OFF, 01=ON)
56
00 or 01
Set the DSP IF filter type
(00=SHARP, 01=SOFT)
57
00 ~ 02
Set the Manual Notch width
(00=WIDE, 01=MID, 02=NAR)
58
00 ~ 02
Set the SSB transmit bandwidth
(00=WIDE, 01=MID, 02=NAR)
( One of following values is applied, depending
on the “COMP” status (ON or OFF):
WIDE (Command: 1A 05 0015),
MID (Command: 1A 05 0016) or
NAR (Command: 1A 05 0017))
5E
00 or 01
MAIN/SUB Tracking function
(00=OFF, 01=ON)
65
00 or 01
Set the IP Plus function
(00=OFF, 01=ON)
D
Command table (Continued)
Cmd. Sub cmd.
Data
Description
17*
3
see p. 10
Send CW messages
18
00
Turn OFF the transceiver
01*
4
Turn ON the transceiver
19
00
Read the transceiver ID
1A* 00
see p. 11
Send/read memory contents
01
see p. 10
Send/read band stacking register contents
02*
6
see p. 13
Send/read memory keyer contents
03
see p. 12
Send/read the selected IF filter width
04
see p. 12
Send/read the selected AGC time constant
05 0001
see p. 12
Tone Control > RX >
Send/read SSB RX HPF/LPF settings
0002
00 ~ 10
Tone Control > RX >
Send/read SSB RX Tone (Bass) level
(00=–5 to 10=+5)
0003
00 ~ 10
Tone Control > RX >
Send/read SSB RX Tone (Treble) level
(00=–5 to 10=+5)
0004
see p. 12
Tone Control > RX >
Send/read AM RX HPF/LPF settings
0005
00 ~ 10
Tone Control > RX >
Send/read AM RX Tone (Bass) level
(00=–5 to 10=+5)
0006
00 ~ 10
Tone Control > RX >
Send/read AM RX Tone (Treble) level
(00=–5 to 10=+5)
0007
see p. 12
Tone Control > RX >
Send/read FM RX HPF/LPF settings
0008
00 ~ 10
Tone Control > RX >
Send/read FM RX Tone (Bass) level
(00=–5 to 10=+5)
0009
00 ~ 10
Tone Control > RX >
Send/read FM RX Tone (Treble) level
(00=–5 to 10=+5)
0010
see p. 12
Tone Control > RX >
Send/read CW RX HPF/LPF settings
0011
see p. 12
Tone Control > RX >
Send/read RTTY RX HPF/LPF settings
0012
see p. 12
Tone Control > RX >
Send/read PSK RX HPF/LPF settings
0013
00 ~ 10
Tone Control > TX >
Send/read SSB TX Tone (Bass) level
(00=–5 to 10=+5)
0014
00 ~ 10
Tone Control > TX >
Send/read SSB TX Tone (Treble) level
(00=–5 to 10=+5)
0015
see p. 12
Tone Control > TX >
Send/read SSB TX bandwidth for wide
0016
see p. 12
Tone Control > TX >
Send/read SSB TX bandwidth for mid
0017
see p. 12
Tone Control > TX >
Send/read SSB TX bandwidth for narrow
0018
00 ~ 10
Tone Control > TX >
Send/read AM TX Tone (Bass) level
(00=–5 to 10=+5)
0019
00 ~ 10
Tone Control > TX >
Send/read AM TX Tone (Treble) level
(00=–5 to 10=+5)
0020
00 ~ 10
Tone Control > TX >
Send/read FM TX Tone (Bass) level
(00=–5 to 10=+5)
0021
00 ~ 10
Tone Control > TX >
Send/read FM TX Tone (Treble) level
(00=–5 to 10=+5)
0022 0000 ~ 0255 Function > Beep Level
(0000=min. to 0255=max.)
0023
00 or 01
Function > Beep Level Limit
(00=OFF, 01=ON)
0024
00 or 01
Function > Beep (Confirmation)
(00=OFF, 01=ON)
0025
00 or 01
Function > Band Edge Beep
(00=OFF, 01=ON)
( ON = Beep sounds with a default amateur
band)
02
Function > Band Edge Beep
(02=ON (User))
03
Function > Band Edge Beep
(03=ON (User) & TX Limit)
15
Remote control
4