D
Command formats (Continued)
•
Data mode with filter width settings
Command: 1A 06
•
IF filter width settings
Command: 1A 03
•
AGC time constant settings
Command: 1A 04
•
SSB transmission passband width settings
Command: 1A 05 0015, 05 0016, 05 0017
q
X X X X
w
01=FIL1
02=FIL2
03=FIL3
00=Data mode OFF*
01=DATA1
02=DATA2
03=DATA3
*
When 00 is set, also set 00 to
w
Mode
Data
Steps
SSB/CW/
RTTY/PSK
0 to 9
50 ~ 500 Hz (50 Hz)
SSB/CW/
PSK
10 to 40
600 Hz ~ 3.6 kHz (100 Hz)
RTTY
10 to 31
600 ~ 2.7 kHz (100 Hz)
AM
0 to 49
200 Hz ~ 10.0 kHz (200 Hz)
Data
AGC time constant (sec.)
SSB/CW/RTTY/PSK
AM
0
OFF
OFF
1
0.1
0.3
2
0.2
0.5
3
0.3
0.8
4
0.5
1.2
5
0.8
1.6
6
1.2
2.0
7
1.6
2.5
8
2.0
3.0
9
2.5
4.0
10
3.0
5.0
11
4.0
6.0
12
5.0
7.0
13
6.0
8.0
X
X
Higher edge: 0= 2500 Hz
1= 2700 Hz
2= 2800 Hz
3= 2900 Hz
Lower edge: 0= 100 Hz
1= 200 Hz
2= 300 Hz
3= 500 Hz
•
RX HPF/LPF setting for each operating mode
Command: 1A 05 0001, 05 0004, 05 0007,
05 0010, 05 0011, 05 0012
X X X X
LPF (Upper edge)
HPF (Lower edge)
*The value of the HPF should be smaller than the LPF.
HPF
00:
Through
01 ~ 20: 100 ~ 2000 Hz
LPF
05 ~ 24: 500~2400 Hz
25:
Through
•
Bandscope edge frequency settings
Command: 1A 05 0182 ~ 05 0217
1 kHz:
0–9
100 Hz:
0 (fix
ed)
100 kHz:
0–9
10 kHz:
0–9
10 MHz:
0–6
1 MHz:
0–9
1 kHz:
0–9
100 Hz:
0 (fix
ed)
100 kHz:
0–9
10 kHz:
0–9
10 MHz:
0–6
1 MHz:
0–9
q
X
0 X X X X X
0 X X X X
w
e
r
t
y
Lower edge
Higher edge
•
Color settings
Command: 1A 05 0172, 0173, 0174, 0219, 0221,
0234, 0243, 0244, 0245, 0246,
0250, 0255, 0256, 0257, 0258
q
0 X X X 0 X X X 0 X X X
w
e
r
t
y
R (Red)
0000 ~ 0255
G (Green)
0000 ~ 0255
B (Blue)
0000 ~ 0255
•
Offset frequency settings
Command: 1A 05 0035, 0036, 0040
1 kHz digit:
0–9
100 Hz digit:
0 (fix
ed)
100 kHz digit:
0–9
10 kHz digit:
0–9
10 MHz digit:
0–9
*
2
1 MHz digit:
0–9
Direction:
00=+ direction 01=– direction
q
0
X
X
X
X
XX
w
e
0
r
*
1
*1 No need to enter for transverter offset frequency setting.
*2
Transverter offset only. Fix to ‘0’ for split offset setting.
Remote control
12