19
CONTROL COMMAND
19-11
Remote control (CI-V) information (Continued)
•
Codes for CW message contents
Command : 17 Up to 30 characters
To send CW messages, use the following character
codes.
Character
ASCII code
0–9
30–39
A–Z
41–5A
a–z
61–7A
/
2F
?
3F
.
2E
−
2D
,
2C
:
3A
Character
ASCII code
’
27
(
28
)
29
=
3D
+
2B
”
22
@
40
Space
20
L
“FF” stops sending CW messages.
L
“^” is used to transmit a string of characters with no
inter-character space.
•
RIT frequency settings
Command : 21 00
10 Hz:
0–9
100 Hz:
0–9
1 Hz:
0–9
1 kHz:
0–9
X
X
X
X
X
X
00: + (plus)
01: – (minus)
•
Repeater tone/tone squelch frequency settings
Command : 1B 00, 1B 01
100Hz digit: 0–2
10 Hz digit: 0–9
1 Hz digit: 0–9
0.1 Hz digit: 0–9
Fixed digit: 0*
Fixed digit: 0*
q
*
0
0
X
X
X
w
e
X
*Not necessary when setting a frequency.
•
UTC Offset setting
Command : 1A 05 0096
X
Shift direction
00: + (plus)
01: − (minus)
Offset time
0000−1400
X X X XX
•
Selected or unselected VFO frequency settings
Command: 25
X X X X X X X X X X 0 0
00: Selected VFO
01: Unselected VFO
Operating frequency data
•
Selected or unselected VFO’s operating mode
and filter settings
Command: 26
Both data and filter settings can be skipped. In that
case, “DATA OFF” and the default filter setting of the
operating mode are automatically selected.
X X X X X X
X X
q
Operating mode setting
e
Filter setting
w
Data mode setting
00: Selected VFO
01: Unselected VFO
q
Operating mode
w
Data mode setting
e
Filter
setting
00: LSB 05: FM
00: Data mode OFF
01: FIL1
01: USB 07: CW-R
01: Data mode ON
02: FIL2
02: AM
08: RTTY-R
03: FIL3
03: CW
04: RTTY
Previous view