19
CONTROL COMMAND
19-9
Remote control (CI-V) information (Continued)
•
Band stacking register
Command: 1A 01
q
X
X
X
X
w
q
Frequency band codes
Code Freq. band Frequency range (unit: MHz)
01
1.8
1.800000–1.999999
02
3.5
3.400000–4.099999
03
7
6.900000–7.499999
04
10
9.900000–10.499999
05
14
13.900000–14.499999
06
18
17.900000–18.499999
07
21
20.900000–21.499999
08
24
24.400000–25.099999
09
28
28.000000–29.999999
10
50
50.000000–54.000000
11
GENE
Other than above
w
Register codes
Code Registered number
01
1 (latest)
02
2
03
3 (oldest)
For example, when sending/reading the oldest
contents in the 21 MHz band, the code “0703” is used.
•
Offset frequency settings
Command : 1A 050031, 050032
1 kHz digit:
0–9
100 Hz digit:
0 (fix
ed)
100 kHz digit:
0–9
10 kHz digit:
0–9
10 MHz digit:
0–9
†
1 MHz digit:
0–9
Direction:
00=+ direction 01=– direction
q
0
X
X
X
X
XX
w
e
0
r
*
*1 There is no need to enter the transverter offset frequency setting.
*2
Transverter offset only. Fix to ‘0’ for split offset setting.
•
Codes for character entries
- Character codes— Letters and Numbers
Character ASCII code Character ASCII code
A–Z
41–5A
a-z
61–7A
0–9
30–39
- Character codes— Symbols
Character ASCII code Character ASCII code
!
21
#
23
$
24
%
25
&
26
\
5C
?
3F
”
22
’
27
`
60
^
5E
+
2B
−
2D
✱
2A
/
2F
.
2E
,
2C
:
3A
;
3B
=
3D
<
3C
>
3E
(
28
)
29
[
5B
]
5D
{
7B
}
7D
|
7C
_
5F
͂
7E
@
40
Command
Set item/selectable characters
1A 00
Memory name
All characters are usable.
1A 050091 Opening message
Uppercase letters, numbers, symbols
(− / . @) and space are usable.
•
Data mode with filter width settings
Command : 1A 06
q
X X X X
w
01=FIL1
02=FIL2
03=FIL3
00=Data mode OFF*
01=Data mode ON
*
When 00 is set, also set 00 to
w
Previous view