ELECTRONIC CIRCULATOR FOR SOLAR THERMAL SYSTEMS - Art. S167
FI.S167.EN.C - 03/2023
Icma SpA - Via Garavaglia, 4 - 20012 Cuggiono (MI) ITALY Tel: +39 02 97249134 - +39 02 97249135 - www.icmaspa.it - [email protected]
Icma SpA - Via Garavaglia, 4 - 20012 Cuggiono (MI) ITALY Tel: +39 02 97249134 - +39 02 97249135 - www.icmaspa.it - [email protected]
6
7
The junction box can rotate at 90°.To change the position of the junction box, follow the operating steps below:
1.
Switch the valves of the inlet and outlet and conduct decompression;
2.
Loosen and remove the four socket head cap screws that fix the pump body;
3.
Rotate the motor to the desired position and match the four screw holes;
4.
Put the four socket head cap screws back and tighten them in the cross-direction order;
5. Open the valve of the inlet and outlet.
Warning
Pumping liquid may be at high temperature and pressure, therefore, liquid
in the system should be drained off or valves on both sides of the pump
must be switched off before removing socket head cap screws.
Change the position of the junction box, the pump should not be started
until the system has been filled with pumping liquid or valves on both sides
of the pump are open.
CAUTION