background image

Heat Pump 

7-Day Programmable 

Hardwired

SC 3201

Programmable Electronic Thermostat

Installation, Operation & Application Guide

For more information on our complete range of American-made 
products – plus wiring diagrams, troubleshooting tips and more, 
visit us at 

www.icmcontrols.com

• 7-Day Programmable
• 2-Stage Heat Pump
• Backlit Display
• Manual Changeover
• Simpleset

®

 Programming

• Title 24 Compliant / No Batteries Required
• Relay Outputs  

(minimum voltage drop in thermostat)

• Ideally Suited for: 

– 

Residential (New Construction/Replacement),  

  Light Commercial

Содержание SC 3201

Страница 1: ...of American made products plus wiring diagrams troubleshooting tips and more visit us at www icmcontrols com 7 Day Programmable 2 Stage Heat Pump Backlit Display Manual Changeover Simpleset Programming Title 24 Compliant No Batteries Required Relay Outputs minimum voltage drop in thermostat Ideally Suited for Residential New Construction Replacement Light Commercial ...

Страница 2: ...e Existing Thermostat 3 To Install Thermostat 3 Wiring Diagram Conversions 5 16 Mode of Operation 17 LED Indicators 18 Starting the Thermostat 19 Testing the Thermostat 20 Operating Modes 22 Setting the Time and Day of the Week 23 Programming 24 Simpleset Programming 26 Factory Preprogramming 26 Personal Program Schedule 27 Troubleshooting 29 ...

Страница 3: ... SimpleComfort 3201 Parts Diagram Fan Switch Reset Button Cool Emer Off On Auto Heat Y2 Y1 E G W2 O B Mode Hold Switch System Switch C L R Mode Hold ...

Страница 4: ... 24 VAC applications only do not use on voltages over 30 VAC All wiring must conform to local and national electrical and building codes Do not use air conditioning when the outdoor temperature is below 50 degrees this can damage your A C system and cause personal injuries Use this thermostat only as described in this manual Important Safety Information Package includes SimpleComfort 3201 programm...

Страница 5: ... to the following section for instructions on how to install this thermostat To Remove Existing Thermostat ELECTRICAL SHOCK HAZARD Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat IMPORTANT Thermostat installation must conform to local and national building and electrical codes and...

Страница 6: ...at base with mounting holes and feed the control wires through the wire opening 9 Use supplied screws to mount thermostat base to wall 10 Insert stripped labeled wires in matching wire terminals See Wiring Diagrams section of this manual Pages 5 16 CAUTION Be sure exposed portion of wires does not touch other wires 11 Tighten screws on terminal block Gently tug wire to be sure of proper connection...

Страница 7: ... Wiring Diagrams SimpleComfort 3201 Electronic Thermostat Conversion to Carrier Split Stream Condensers and Heat Pump Systems SC 3201 Electronic Thermostat ...

Страница 8: ... SimpleComfort 3201 Electronic Thermostat Conversion to Coleman 3000 Series Heat Pump Systems SC 3201 Electronic Thermostat ...

Страница 9: ... SimpleComfort 3201 Electronic Thermostat Conversion to Comfortmaker CYC Series Heat Pump Systems SC 3201 Electronic Thermostat capped capped ...

Страница 10: ... SimpleComfort 3201 Electronic Thermostat Conversion to Heil Quaker 867 814 Series and PH50 Series Heat Pump Systems SC 3201 Electronic Thermostat capped ...

Страница 11: ... SimpleComfort 3201 Electronic Thermostat Conversion to Payne Reliant and Endura Model Heat Pump Systems SC 3201 Electronic Thermostat capped ...

Страница 12: ...10 SimpleComfort 3201 Electronic Thermostat Conversion to Rheem Ruud PGB PFA PCB PLA and PKA Series Heat Pump Systems SC 3201 Electronic Thermostat ...

Страница 13: ...11 SimpleComfort 3201 Electronic Thermostat Conversion to Goodman Janitrol Trane American Standard Heat Pumps SC 3201 Electronic Thermostat capped capped ...

Страница 14: ...12 SimpleComfort 3201 Electronic Thermostat Conversion to York E1CS E1FB E1FH Heat Pump Systems SC 3201 Electronic Thermostat ...

Страница 15: ...13 SimpleComfort 3201 Electronic Thermostat Conversion to Lennox CB19 Heat Pump Systems SC 3201 Electronic Thermostat ...

Страница 16: ...14 SimpleComfort 3201 Electronic Thermostat Conversion to Lennox HP19 and HP20 Heat Pump Systems SC 3201 Electronic Thermostat ...

Страница 17: ...15 SimpleComfort 3201 Electronic Thermostat Conversion to Lennox HP21 With CB21 PCB Heat Pump Systems SC 3201 Electronic Thermostat ...

Страница 18: ...16 SimpleComfort 3201 Electronic Thermostat Conversion to Lennox HP22 With CB19 PCB Heat Pump Systems SC 3201 Electronic Thermostat ...

Страница 19: ...3 The new temperature setpoint is automatically saved in memory Setting a New Temperature Differential 1 The default temperature differential is 1 When your room temperature varies by 1 F the thermostat turns on your system If you notice your system turning on and off too frequently increase the temperature differential 2 Place the System switch in OFF position 3 Press both and buttons simultaneou...

Страница 20: ... first stage and is not adjustable CHECK Red When this turns on a malfunction has occurred somewhere in the heat pump system Please contact a qualified service technician as soon as possible to check your system EMER Red This light turns on whenever the emergency heat is manually selected System switch is in the EMER position While in the emergency Heat mode the heat pump compressor is off and the...

Страница 21: ...s can damage your air conditioning system and cause personal injuries 1 Move the Fan Auto On switch to the Auto position On position runs indoor fan continuously 2 Move the System switch to Cool or Heat depending on the season Starting the Thermostat Fan Switch Mode Hold Switch System Switch ...

Страница 22: ...re and the A C should turn Off There may be a fan delay on your system Note There is a four minute time delay to protect the compressor after it turns Off To bypass the four minute delay slide the System switch to Off and back to Cool mode Heat Test 1 Slide System switch to Heat position Heat mode screen is displayed 2 Adjust the set temperature so it is 5 degrees above the room temperature 3 Heat...

Страница 23: ...es above room temperature 3 Second stage heat should come on within a few seconds Aux LED lights 4 Adjust the set temperature 2 degrees below the room temperature and the heat should turn off There may be a fan delay on your system Fan Test 1 Slide Fan switch to On position 2 Indoor fan turns on 3 Slide Fan switch to Auto position 4 Indoor fan turns off ...

Страница 24: ...dule that is stored in memory Emergency Mode In this mode the thermostat controls the heating system but bypasses the heat pump system Press the Mode button to enter exit the Program Emer Heat mode In Program Emer Heat PROG displays mode the thermostat will follow the program schedule that is stored in memory Note Program Emer Heat mode follows the same schedule set for Program Heat mode Hold When...

Страница 25: ...s the day currently set on the thermostat 1 Monday 2 Tuesday etc 5 Press the or button to set the correct day of the week that today is Note Sliding the System switch to Cool or Heat positions will lock the values into memory You may also press the button to enter your programming schedule 2 Press the button in for 6 seconds 3 Press the or button to adjust the time Setting the Time and Day of the ...

Страница 26: ...for each period in your program 1 Place System switch in OFF position 2 Press the button for 6 seconds 3 Press the button twice Day is displayed 1 7 4 Press the or button to change the day you want to program 1 Monday 2 Tuesday etc 5 Press the button to advance to the next parameter Note You can always press the button to return to the previous parameter Period is displayed MORN DAY EVE NITE 6 Pre...

Страница 27: ...e 11 Press the button to advance to the next screen Cool temperature is displayed 45 F to 85 F 12 Press the or button to adjust cool set temperature 13 Press the button to advance to the next screen Repeat steps 1 13 to program each day of the week individually or use the Simpleset feature see Page 26 to program every day the same as Monday When programming is complete slide the System switch to H...

Страница 28: ...days of the week will count down from 7 to 1 and this will lock the settings into memory Once the schedule is locked in you can go through each day and make any changes you require This feature speeds up the programming of the standard weekday weekend schedule 3 Slide the System switch to Heat or Cool to exit Programming Mode The SC3201 comes preprogrammed with the following schedule MORN 6 00 AM ...

Страница 29: ...NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL MONDAY 1 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL TUESDAY 2 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL WEDNESDAY 3 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL THURSDAY 4 Personal Program Schedule ...

Страница 30: ...Schedule continued MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FRIDAY 5 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL SATURDAY 6 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL SUNDAY 7 ...

Страница 31: ...Differential Page 17 Thermostat does not follow program Verify it is operating in Program mode PROG displays solid check time AM PM check if in Hold mode PROG flashes in Hold mode PROGram flashes in Hold mode Press Hold button to remove from Hold mode Fan runs continuously Check Fan On Auto switch fan runs continuously when fan switch is in ON position Room temperature is not correct Verify wall h...

Страница 32: ...er to permit the Seller to properly administer the warranty the Buyer shall 1 Notify the Seller promptly of any claim submitting date code information or any other pertinent data as requested by the Seller 2 Permit the Seller to inspect and test the product claimed to be defective Items claimed to be defective and are determined by Seller to be non defective are subject to a 30 00 per hour inspect...

Отзывы: