Wiring Diagrams

Fan 

Control

4 or 5 Wire,

Fan 

Control

Содержание SC 3006

Страница 1: ...us at www icmcontrols com 7 Day Programmable Single Stage Heat Pump Non Heat Pump Systems Backlit Display Single Stage Heat Cool Systems Field Calibration Auto Changeover Button Lockout Function Compatible with Gas Oil or Electric Simpleset Programming Remote Temperature Sensor Capability Title 24 Compliant No Batteries Required Relay Outputs minimum voltage drop in thermostat Ideally Suited for R...

Страница 2: ...stat 2 Remote Sensor Installation Optional 4 Wiring Diagrams 5 Configuration Mode 8 Starting the Thermostat 10 Testing the Thermostat 11 Mode of Operation 12 Operating Modes 13 Setting the Time and Day of the Week 14 Programming 15 Simpleset Programming 17 Lockout Function 17 Factory Preprogramming 18 Personal Program Schedule 18 Troubleshooting 20 ...

Страница 3: ...ges over 30 VAC Do not short across terminals of gas valve or system control to test operation this will damage your thermostat and void your warranty All wiring must conform to local and national electrical and building codes Do not use air conditioning when the outdoor temperature is below 50 degrees this can damage your A C system and cause personal injuries Use this thermostat only as describe...

Страница 4: ...ve existing thermostat base from wall 6 Refer to the following section for instructions on how to install this thermostat To Install Thermostat ELECTRICAL SHOCK HAZARD Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat IMPORTANT Thermostat installation must conform to local and natio...

Страница 5: ...through wire opening 9 Use supplied screws to mount thermostat base to wall 10 Insert stripped labeled wires in matching wire terminals See Wiring Diagrams section of this manual Page 5 CAUTION Be sure exposed portion of wires does not touch other wires 11 Tighten screws on terminal block Gently tug wire to be sure of proper connection Double check that each wire is connected to the proper termina...

Страница 6: ...sed Do not run remote sensor wire in conduit with other wires Wire 1 should run between the S1 terminal on the thermostat and the S1 terminal on the remote sensor Wire 2 should run between the S2 terminal on the thermostat and the S2 terminal on the remote sensor Connect the shielding of the wire to the S2 terminal on the thermostat 5 Disable the main sensor R12 on the thermostat by cutting it fro...

Страница 7: ... Wiring Diagrams Fan Control 4 or 5 Wire Fan Control ...

Страница 8: ... ...

Страница 9: ... ...

Страница 10: ...n for 6 seconds Configuration Mode Settings The setup screens for configuration mode are as follows 1 Temperature scale F or C Choose Fahrenheit or Celsius Press the or button to select Press the button to advance to the next screen 2 Differential 1 F 5 F 1 C 3 C Set the number of degrees between your turn on temperature and your setpoint temperature Press the or button to set differential value P...

Страница 11: ... lockout allows adjustment of the set temperatures to the maximum heat set temperature selected in Step 6 and minimum cool set temperature selected in Step 7 Note The mode cannot be changed when the thermostat is locked Press the or button to select Press the button to advance to the next screen 6 Maximum Heat Setpoint 45 F 90 F 7 C 32 C Adjust to control the maximum heat set temperature allowed P...

Страница 12: ...e Mode 8 Room temperature offset 9 F to 9 F 5 C to 5 C Adjust to calibrate displayed room temperature to match actual room temperature Press the button to advance to the next screen 9 Maximum compressor cycles allowed per hour d 2 6 as many as needed 2 6 maximum cycles hour Press the button to advance to the next screen Configuration Mode Settings continued ON 10 Status indicator light ON OFF Pres...

Страница 13: ... room temperature and the A C should turn off There may be a fan delay on your system Note There is a four minute time delay to protect the compressor after it turns off Heat Test 1 Press mode button until heat mode is displayed 2 Adjust the set temperature so it is 5 degrees above the room temperature 3 Heat should come on Red LED turns ON 4 Adjust the set temperature 2 degrees below the room tem...

Страница 14: ...the compressor come on for 4 minutes after it turns off This protects your compressor The SC3006 has five possible operating modes OFF Heat Cool Heat Cool and Program mode In off mode the thermostat will not turn on heating or cooling devices The manual fan can be turned on in all operating modes using the fan switch In heat mode the thermostat controls the heating system In the Cool mode the ther...

Страница 15: ...ode In this mode the thermostat controls the heating system Note For heat pumps there is a four minute delay for your compressor to restart after it has turned off Program Mode In this mode the program function is on PROG displays and the thermostat will automatically be controlled by the set program schedule Program mode can function with heat mode cool mode or heat cool mode The program schedule...

Страница 16: ...or button to adjust the time 4 Press the button while the time is displayed The display shows the day currently set on the thermostat 1 Monday 2 Tuesday etc 5 Press the or button to set the correct day of the week that today is Note Press the button in for 5 seconds to lock values into memory and return to the OFF mode or press the button once to enter programming Setting the Time and Day of the W...

Страница 17: ...or each period in your program 1 Press the button until you are in the OFF mode 2 Press the button for 6 seconds 3 Press the button twice Day is displayed 1 7 4 Press the or button to change the day you want to program 1 Monday 2 Tuesday etc 5 Press the button to advance to the next screen Note You can always press the button to return to the previous parameter Period is displayed MORN DAY EVE NIT...

Страница 18: ... temperature is displayed 45 F to 90 F Note Cool cannot be set lower than heat temperature 12 Press the or button to adjust cool set temperature 13 Press the button to advance to the next screen Repeat steps 1 13 to program each day of the week individually or use the Simpleset feature see Page 17 to program every day the same as Monday When programming is complete press and hold the button in for...

Страница 19: ...emory Once the schedule is locked in you can go through each day and make any changes you require This feature speeds up the programming of the standard weekday weekend schedule 3 Press and hold the button for 5 seconds to exit program mode and return to the OFF mode The SC3006 thermostat has a button lockout feature so the settings cannot be changed or tampered with With the lockout activated any...

Страница 20: ...DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL TUESDAY 2 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL WEDNESDAY 3 The SC3006 comes preprogrammed with the following schedule MORN 6 00 AM DAY 8 00 AM EVE 6 00 PM NITE 10 00 PM HEAT 70 F HEAT 62 F HEAT 70 F HEAT 62 F COOL 78 F COOL 85 F COOL 78 F COOL 82 F MONDAY thru SUNDAY Personal Program Schedule ...

Страница 21: ...TE HEAT HEAT HEAT HEAT COOL COOL COOL COOL THURSDAY 4 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL FRIDAY 5 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL SATURDAY 6 MORN DAY EVE NITE HEAT HEAT HEAT HEAT COOL COOL COOL COOL SUNDAY 7 ...

Страница 22: ...M check if in 2 hour program override Fan runs continuously Check Fan On Auto switch fan runs continuously in On position Status indicator light not on during call Turn status indicator function on see Configuration Mode Setting 10 Page 10 Room temperature is not correct Verify wall hole for wires is plugged with putty or insulation calibrate thermostat see Configuration Mode Setting 8 Page 10 If ...

Страница 23: ...er to permit the Seller to properly administer the warranty the Buyer shall 1 Notify the Seller promptly of any claim submitting date code information or any other pertinent data as requested by the Seller 2 Permit the Seller to inspect and test the product claimed to be defective Items claimed to be defective and are determined by Seller to be non defective are subject to a 30 00 per hour inspect...