9. Error Type

Display

Error type

Causes

Action

Release

Operation

Evaporator 

temperature 

error

When the Evaporator temperature 

is 32℉ or more after 30 minutes 

passed during the ice making

Check refrigerant 

leakage

Check sensor and 

attachment abnormality

Resupply power 

after resolving 

cooling problem

Stop ice 

making

Evaporator 

temperature 

error

When the Evaporator temperature 

is over 23℉ after 30 minutes 

passed

Check refrigerant 

leakage

Check sensor and 

attachment abnormality

Resupply power 

after resolving 

cooling problem

Keep on ice 

making

Temperature 
sensor error 

Displayed when temperature 

sensor is open or shorted.

Check sensor and 

attachment abnormality

Start operation 

after sensor part 

repair

Stop ice 

making

High 

pressure 

switch error

Condenser dust, fan motor failure, 

cold cycle abnormality, etc.

Remove dust,

Check Fan motor 

Check for abnormal 

cold cycle

Automatic return 

after action

Stop 

compressor,

Stop 

motor after 

operating 10 

seconds.

High 

pressure 

switch error

Occurs when High pressure 

switch is OPEN 3 times or more

Contact service 

representative

Start operation 

after action

Stop 

compressor,

Stop 

motor after 

operating 10 

seconds.

Water supply 

error

When water level is not detected 

by the water level sensor due to 

no water supply for 120 seconds.

Water supply pressure 

check

Water level sensor 

check

Start operation 

after action

Stop ice 

making

Water level 

sensor defect

At the start of ice making, when 

the upper and lower limits are 

not detected by the water level 

sensor for 60 seconds

Replacement of Water 

Level Sensor

Start operation 

after action

Stop ice 

making

Motor 

restraint

Occurs when Evaporator inlet / 

outlet temperature is -4℉ less      

Poor water supply, Agitator 

restraint, Ice jams due to scale

Unlock ice jams

Check water supply 

line

Check motor restraint 

fault 

Start operation 

after action.

Machine stops 

after 3 repetitions

Stop ice 

making

① When Error occurs, the front use button (ICE-WATER-ICE & WATER) of the door lights alternately
    to the left and right. Restart after action. 
② When the button is lit alternately to the left and right, open the door and press the bottom setting 
    button of the control buttons, Error display will appear.

Содержание ID-0160-AN

Страница 1: ...This product is designed for indoor installation Please be sure to install it indoors The external appearance design color and or components of this machine may be changed without prior notice for th...

Страница 2: ...t the product Button operation Function button description FND display window Three drainage functions forced drainage automatic draining water drainage Stop switch 7 Maintenance repair and disinfecti...

Страница 3: ...nt of improper use Warning Caution SHOULD BE DONE PROHIBITION GROUNDED DO NOT DISASSEMBLE DO NOT TOUCH DISCONNECT POWER PLUG An electrical fire may be caused by a receptacle holding more than one item...

Страница 4: ...a risk of fire or electric shock There is a risk of fire due to electric shock or short circuit Risk of explosion or fire Do not place heavy objects or containers containing water on the ice maker Do...

Страница 5: ...r become damaged The cord or plug may be peeled and there is a risk of fire or electric shock If the cord or plug is peeled or damaged be sure to ask the service to replace it Disassembly forbidden Do...

Страница 6: ...ck due to short circuit Do not plug in multiple plugs at the same time Connecting multiple plugs to a power strip will cause a fire Disconnect power plug When not in use for a long time remove ice and...

Страница 7: ...aker Caution If there is a risk of slippery water or oil on the floor near the ice maker please wipe it Hand over When transferring this ice maker to another person please hand it along with the instr...

Страница 8: ...Condensation method Air cooled Refrigerant R 134A Deceleration motor Power Supply AC 115 V 60 1PH Rated output 40 W Discharging method Solenoid Installation environment standard Specification 50 100...

Страница 9: ...arance and Size Front Top Bottom Rear 23 9 Upper vent 25 25 4 Drain box Height adjustable feet Ice exit Ice discharge lever 13 8 Display panel 13 8 350mm 25 25 6 634 650mm 23 8 605mm Water inlet Drain...

Страница 10: ...10 We Think of Customer Satisfaction Ice making wash switch Drain outlet drain box Power switch Bottom filter 208 8 7 220mm Left Right...

Страница 11: ...ere the space with the wall is reserved For normal operation install the ice maker at least 7 8 away from the wall For cleaning and maintenance of the auger 39 4 space should be reserved above the top...

Страница 12: ...observe the following Since the product makes use of water proper water supply and draining facility are required Water may leak during installation or operation for diverse reasons Thus proper draini...

Страница 13: ...d then spread the bottom left and right then lift up to separate 3 Front Panel Loosen the two lower left and right screws pull the lower part toward the front and lower it to disassemble Please assemb...

Страница 14: ...upply and drainage Please connect a hose with an inner diameter of 20mm 0 78 or more for the ice making drain hose and the drain outlet should be 5cm 1 97 above the drain floor level If the drain outl...

Страница 15: ...water pipes and non insulated materials do not have a grounding effect POWER OUTLET Copper plate Equal to or more than 75 cm Ground wire A Ground wire A Ground wire Grounding terminals Grounding is n...

Страница 16: ...ont door and turn on the power switch to start the Ice making operation Turn the ICE MAKING OFF WASH switch to ICE MAKING There is a slight difference depending on the ambient temperature and water te...

Страница 17: ...ously discharge ice and water for the time set in F1 When ERROR occurs ICE WATER ICE WATER button will flicker in order and will disappear when restarting after the action against the ERROR Service cy...

Страница 18: ...4th digits drain interval 1 0 hour 0 5 9 5 hours every 30 minutes F 6 ICE WATER volume control 1st 2nd digits Ice time Default 5 seconds up to 99 seconds 3rd 4th digits Water time Default 5 seconds u...

Страница 19: ...itial water draining function F 4 Turn the power switch off and then on again the ICE MAKING OFF WASH switch at ICE MAKING position to operate the function Clean the water line and ice making cylinder...

Страница 20: ...erve the following points Caution 1 Turn on the power switch and press the DOWN SET button at the same time for 3 seconds with any signal on the FND window Forced drainage will be done for 30 seconds...

Страница 21: ...repared as described in the instructions for disinfection in the manual into the evaporator condensate drain pan 2 Take care not to overflow the drain pan 3 This disinfectant solution will flow out th...

Страница 22: ...mediately with a mild detergent However when the rust has gotten really bad it must be removed with 15 nitric acid solution or commercially available stainless steel cleaner 4 Rust from exhaust gas or...

Страница 23: ...ash the water level sensor thoroughly with clean water Fix the level sensor to the correct position 9 Switch the ICE MAKING OFF WASH switch to the ICE MAKING position to start the ice maker Keep it ru...

Страница 24: ...disinfectant solution is exhausted and the ice production stops 12 Switch the ICE MAKING OFF WASH switch to the WASH position and let the remaining water drain out for 5 minutes 13 Turn the power swit...

Страница 25: ...25 8 Circuit Diagram...

Страница 26: ...ure switch error Occurs when High pressure switch is OPEN 3 times or more Contact service representative Start operation after action Stop compressor Stop motor after operating 10 seconds Water supply...

Страница 27: ...eck the water source 4 Is water valve working Check and contact the customer service center 3 Takes too long to make ice cubes 1 Ice maker is too dirty too much dust Air cooled type Disassemble the fr...

Страница 28: ...age due to external impact or dropping 8 Failure due to natural disasters lightning fire earthquake flood tsunami etc 9 Consumable parts have reached end of life packing cleaning brush etc 10 If the m...

Страница 29: ...29 MEMO...

Страница 30: ...30 We Think of Customer Satisfaction MEMO...

Страница 31: ...31 MEMO...

Страница 32: ...3240453 20 Online Internet Service http www icetro com...

Отзывы: