※ The ice maker should be cleaned and disinfected at least twice a year.

    More frequent cleaning and disinfection may be required.

1. Washing solution

   

Use a scale remover that is not harmful to human body by diluting with water, and use more 

   amount if necessary.

   It is important to use the diluted cleaning solution immediately for safety and maximum effect.

2. Washing procedure

    

1) Shut off the water supply by locking the valve of the water line of the ice maker.

    2) Switch the ICE MAKING-OFF-WASH switch to the "WASH" position.

    3) The water in the water tank is drained through the evaporator cylinder and washing is done 

        by this (max. 5 minutes).

    4) Turn the ICE MAKING-OFF-WASH switch to "OFF" position.

    5) Remove all ice from the ice maker and reservoir.

    6) Pour the wash solution into the wash solution inlet until the evaporator assembly 

       and the water tank are full.

       (Until the wash solution overflows to the drain box)

    7) Leave the ice maker for 10 minutes before starting operation. If the water supply hose is 

        clogged in step 7, remove it before operation.

    8) As described below, please disassemble and clean the water level sensor (high and low) 

        if it is in bad water condition.

        If not, proceed to step 9.

       ⓐ Remove the water level sensor from the water tank cover.

       ⓑ Clean the level sensor with washing solution.

       ⓒ Wash the water level sensor thoroughly with clean water.

       ⓓ Fix the level sensor to the correct position.

   9)  Switch the ICE MAKING-OFF-WASH switch to the " ICE MAKING " position to start the ice maker.

       Keep it running until ice making stops.

(※ Water supply valve should be locked so that water 

       is not supplied.) 

  10) Switch the front ICE MAKING-OFF-WASH switch to the "WASH" position, and drain the remaining 

       water in the water tank and evaporator cylinders for 5 minutes.

  11) Switch the ICE MAKING-OFF-WASH switch to the "OFF" position.

  12) Open the water supply valve of the ice maker, and switch the ICE MAKING-OFF-WASH switch 

       to the " ICE MAKING " position so that water can be supplied to the water tank.

  13) When the geared motor is activated, switch the ICE MAKING-OFF-WASH switch to the "WASH" 

       position and drain the water (drain is possible for 5 minutes).

  14) Turn OFF the power switch and disconnect the power cord from the outlet.

How to clean and disinfect

 

 

 

Make sure to comply with the following.

  

  

 Do not use ammonia-based detergent to prevent damage to the personnel or the ice maker itself.

  

 Cleaning and sterilizing must be conducted in accordance with the instructions on the user manual.

 

 Always wear protective gloves and goggle to prevent skin or eye from coming into contact 

    with the sterilizing solution.

  ●

 Do not use the ice made with the cleaning or sterilizing solution after cleaning and sterilizing. 

    Make sure that no sterilizing solution is left on any part of the ice maker and the ice storage bin.

Warning

Содержание ID-0160-AN

Страница 1: ...This product is designed for indoor installation Please be sure to install it indoors The external appearance design color and or components of this machine may be changed without prior notice for th...

Страница 2: ...t the product Button operation Function button description FND display window Three drainage functions forced drainage automatic draining water drainage Stop switch 7 Maintenance repair and disinfecti...

Страница 3: ...nt of improper use Warning Caution SHOULD BE DONE PROHIBITION GROUNDED DO NOT DISASSEMBLE DO NOT TOUCH DISCONNECT POWER PLUG An electrical fire may be caused by a receptacle holding more than one item...

Страница 4: ...a risk of fire or electric shock There is a risk of fire due to electric shock or short circuit Risk of explosion or fire Do not place heavy objects or containers containing water on the ice maker Do...

Страница 5: ...r become damaged The cord or plug may be peeled and there is a risk of fire or electric shock If the cord or plug is peeled or damaged be sure to ask the service to replace it Disassembly forbidden Do...

Страница 6: ...ck due to short circuit Do not plug in multiple plugs at the same time Connecting multiple plugs to a power strip will cause a fire Disconnect power plug When not in use for a long time remove ice and...

Страница 7: ...aker Caution If there is a risk of slippery water or oil on the floor near the ice maker please wipe it Hand over When transferring this ice maker to another person please hand it along with the instr...

Страница 8: ...Condensation method Air cooled Refrigerant R 134A Deceleration motor Power Supply AC 115 V 60 1PH Rated output 40 W Discharging method Solenoid Installation environment standard Specification 50 100...

Страница 9: ...arance and Size Front Top Bottom Rear 23 9 Upper vent 25 25 4 Drain box Height adjustable feet Ice exit Ice discharge lever 13 8 Display panel 13 8 350mm 25 25 6 634 650mm 23 8 605mm Water inlet Drain...

Страница 10: ...10 We Think of Customer Satisfaction Ice making wash switch Drain outlet drain box Power switch Bottom filter 208 8 7 220mm Left Right...

Страница 11: ...ere the space with the wall is reserved For normal operation install the ice maker at least 7 8 away from the wall For cleaning and maintenance of the auger 39 4 space should be reserved above the top...

Страница 12: ...observe the following Since the product makes use of water proper water supply and draining facility are required Water may leak during installation or operation for diverse reasons Thus proper draini...

Страница 13: ...d then spread the bottom left and right then lift up to separate 3 Front Panel Loosen the two lower left and right screws pull the lower part toward the front and lower it to disassemble Please assemb...

Страница 14: ...upply and drainage Please connect a hose with an inner diameter of 20mm 0 78 or more for the ice making drain hose and the drain outlet should be 5cm 1 97 above the drain floor level If the drain outl...

Страница 15: ...water pipes and non insulated materials do not have a grounding effect POWER OUTLET Copper plate Equal to or more than 75 cm Ground wire A Ground wire A Ground wire Grounding terminals Grounding is n...

Страница 16: ...ont door and turn on the power switch to start the Ice making operation Turn the ICE MAKING OFF WASH switch to ICE MAKING There is a slight difference depending on the ambient temperature and water te...

Страница 17: ...ously discharge ice and water for the time set in F1 When ERROR occurs ICE WATER ICE WATER button will flicker in order and will disappear when restarting after the action against the ERROR Service cy...

Страница 18: ...4th digits drain interval 1 0 hour 0 5 9 5 hours every 30 minutes F 6 ICE WATER volume control 1st 2nd digits Ice time Default 5 seconds up to 99 seconds 3rd 4th digits Water time Default 5 seconds u...

Страница 19: ...itial water draining function F 4 Turn the power switch off and then on again the ICE MAKING OFF WASH switch at ICE MAKING position to operate the function Clean the water line and ice making cylinder...

Страница 20: ...erve the following points Caution 1 Turn on the power switch and press the DOWN SET button at the same time for 3 seconds with any signal on the FND window Forced drainage will be done for 30 seconds...

Страница 21: ...repared as described in the instructions for disinfection in the manual into the evaporator condensate drain pan 2 Take care not to overflow the drain pan 3 This disinfectant solution will flow out th...

Страница 22: ...mediately with a mild detergent However when the rust has gotten really bad it must be removed with 15 nitric acid solution or commercially available stainless steel cleaner 4 Rust from exhaust gas or...

Страница 23: ...ash the water level sensor thoroughly with clean water Fix the level sensor to the correct position 9 Switch the ICE MAKING OFF WASH switch to the ICE MAKING position to start the ice maker Keep it ru...

Страница 24: ...disinfectant solution is exhausted and the ice production stops 12 Switch the ICE MAKING OFF WASH switch to the WASH position and let the remaining water drain out for 5 minutes 13 Turn the power swit...

Страница 25: ...25 8 Circuit Diagram...

Страница 26: ...ure switch error Occurs when High pressure switch is OPEN 3 times or more Contact service representative Start operation after action Stop compressor Stop motor after operating 10 seconds Water supply...

Страница 27: ...eck the water source 4 Is water valve working Check and contact the customer service center 3 Takes too long to make ice cubes 1 Ice maker is too dirty too much dust Air cooled type Disassemble the fr...

Страница 28: ...age due to external impact or dropping 8 Failure due to natural disasters lightning fire earthquake flood tsunami etc 9 Consumable parts have reached end of life packing cleaning brush etc 10 If the m...

Страница 29: ...29 MEMO...

Страница 30: ...30 We Think of Customer Satisfaction MEMO...

Страница 31: ...31 MEMO...

Страница 32: ...3240453 20 Online Internet Service http www icetro com...